ISITC SET
ip-switch N
NTE
SECM
Single button and
radio in SE mode
Single button and
radio in CM mode
Mid-stop
timer
Timer is enabled
from mid-stop only
Timer is enabled
from both mid-stop
and full open
T or TS mode must be
selected to enable a timer
for mid-stop
elay on
reverse
elay on reverse
is . seconds
elay on reverse
is . seconds
Nice recommends . sec
delay on reverse for all
applications
Motor
direction
everse motor
direction
Standard motor
direction
See Note below
NTE If motor direction is reversed, the open and close limit switches are automatically reversed. owever, the
advanced close limit switch needs to be manually changed. To do this, disconnect the wires from the advanced
closed limit switch and re-connect to the auxiliary limit switch provided.
STATS E
E Status Cause
ault N -rimary safety devices not connected to
or not functioning properly
-Safety devices are activated
-k hm resistor between S S removed
or faulty
ault linking
- Interlock is activated.
- Interlock umper is not connected.
un-out timer N - un-out timer has elapsed
elay on close timer
linking
- elay on close timer is counting.
- Selector dial is set to un-timer.
Timer to close linking
Timer to close is counting.
Safetyhoto N
-rimary safety devices not connected to
or not functioning properly
-Safety devices are activated
-k hm resistor between S S removed
or faulty
Mid. Stop N
oor is at Mid-stop position.
Close imit N
Close limit switch is activated.
pen imit N
pen limit switch is activated.
Stop N
-
Stop button connected and functioning
- Stop push button is activated or the stop
circuit is open.
Close elay linking
- oor is closing.
- Close relay is activated.
pen elay linking
- oor is opening.
- pen relay is activated.
ower N AC power to logic board is N.