EasyManuals Logo

Nice Robus 400 User Manual

Nice Robus 400
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
6
2.2) Typical system
Figure 2 shows a typical system for automating a sliding gate using ROBUS
2
1 Key-operated selector switch
2 Photocells on post
3 Photocells
4 Main fixed edge (optional)
5 Main movable edge
6 “Open” stop bracket
7 Rack
8 Secondary fixed edge (optional)
9 Flashing light with incorporated aerial
10 ROBUS
11 “Closed” stop bracket
12 Secondary movable edge (optional)
13 Radio-transmitter
2.3) List of cables
Figure 2 shows the cables needed for the connection of the devices in a typical installation; table 5 shows the cable characteristics.
The cables used must be suitable for the type of installation; for example, an H03VV-F type cable is recommended for indoor
applications, while H07RN-F is suitable for outdoor applications.
!
Note 1: power supply cable longer than 30 m may be used provided it has a larger gauge, e.g. 3x2,5mm
2
, and that a safety grounding sys-
tem is provided near the automation unit.
Note 2: If the “BLUEBUS” cable is longer than 30 m, up to 50 m, a 2x1mm
2
cable is needed.
Note 3: A single 2x0,5mm
2
cable can be used instead of two 4x0,5mm
2
cables.
Note 4: Please refer to Chapter “7.3.2 STOP Input” in situations where there is more than one edge, for information about the type of con-
nection recommended by the manufacturer.
Note 5: special devices which enable connection even when the leaf is moving must be used to connect movable edges to sliding leaves.
Connection Cable type Maximum length allowed
A: Power line 1 3x1,5mm
2
cable 30m (note 1)
B: Flashing light with aerial 1 2x0,5mm
2
cable 20m
1 RG58 type shielded cable 20m (recommended less than 5 m)
C: Photocells 1 2x0,5mm
2
cable 30m (note 2)
D: Key-operated selector switch 2 2x0,5mm
2
cable (note 3) 50m
E: Fixed edges 1 2x0,5mm
2
cable (note 4) 30m
F: Movable edges 1 2x0,5mm
2
cable (note 4) 30m (note 5)
Table 5: List of cables
2
43 38
10
2
6
11
7
9
13
1251
EC F
D
C
F
A
B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice Robus 400 and is the answer not in the manual?

Nice Robus 400 Specifications

General IconGeneral
ModelRobus 400
TypeSliding Gate Opener
Power Supply230 V AC
Motor Power250 W
Motor Voltage24 V DC
Max Gate Weight400 kg
Protection RatingIP44
Operating Temperature-20°C to +50°C
Speed0.34 m/s
Max Gate Speed0.34 m/s
Safety FeaturesObstacle detection