14
EN
TABLE 21
Programming leds on control unit
Led 1 Description
Off During normal operation the device indicates “Automatic Closing” is not active.
On During normal operation the device indicates “Automatic Closing” is active.
Itashes • Function programming in progress.
•IfitashestogetherwithL2,itmeansthattheusermustcarryoutthedevicerecognitionphase(seepar.4.3).
Led 2 Description
Off During normal operation the device indicates “Close after photo” is not active.
On During normal operation the device indicates “Close after photo” is active.
Itashes • Function programming in progress.
•IfitashestogetherwithL1,itmeansthattheusermustcarryoutthedevicerecognitionphase(seepar.5.3).
Led 3 Description
Off During normal operation the device indicates “Always close” is not active.
On During normal operation the device indicates “Always close” is active.
Itashes • Function programming in progress.
•IfitashestogetherwithL4,itmeansthattheusermustcarryoutthegatelengthrecognitionphase(refertoParagraph5.4
Recognition length of the gate).
Led 4 Description
Off During normal operation the device indicates “Standby” is not active.
On During normal operation the device indicates “Standby” is active.
Itashes • Function programming in progress.
•IfitashestogetherwithL3,itmeansthattheusermustcarryoutthegatelengthrecognitionphase(refertoParagraph5.4
Recognition length of the gate).
Led 5 Description
Off During normal operation the device indicates “Thrust” is active.
On During normal operation the device indicates “Thrust” is active.
Itashes Function programming in progress.
Led 6 Description
Off Duringnormaloperationthedeviceindicates“Preashing”isnotactive.
On Duringnormaloperationthedeviceindicates“Preashing”isactive.
Itashes Function programming in progress.
Led 7 Description
Off During normal operation the device indicates that the CLOSE input activates a closing manoeuvre.
On During normal operation the device indicates that the CLOSE input activates a partial closing manoeuvre.
Itashes Function programming in progress.
Led 8 Description
Off DuringnormaloperationthedeviceindicatesthatRUNisconguredasMaster.
On DuringnormaloperationthedeviceindicatesthatRUNisconguredasSlave.
Itashes Function programming in progress.