15
EN
TECHNICAL SPECIFICATIONS OF PRODUCT
WARNINGS: •Alltechnicalspecicationsstatedinthissectionrefertoanambienttemperatureof20°C(±5°C).•NiceS.p.a.reservestherighttoapply
modicationstoproductsatanytimewhendeemednecessary,maintainingthesameintendeduseandfunctionality.
Model: RUN400HS - RUN400HS/V1 RUN1200HS - RUN1200HS/V1
Type Electromechanical gearmotor for automatic movement of sliding gates for industrial use complete with elec-
tronic control unit.
Pinion Number of teeth 18; Module 4 *
Maximum torque on start-up [cor-
responds to ability of generating the
force required to move the leaf]
12,3 Nm
(340 N)
28,4 Nm
(790 N)
Nominal torque [corresponds to the
ability of generating the force to main-
tain the leaf in movement]
5,6 Nm
(157 N)
8,2 Nm
(320 N)
Speed (no load) 42 m/min 22 m/min
Speed (at nominal torque) 32 m/min 19 m/min
Maximum frequency of operating
cycles (at nominal torque)
11 cycles/hour (264 cycles/day), for a gate of 15m
(equal to a cycle of 63%), (the control unit limits cycles
tothemaximumnumberspeciedintables2and3)**
7-8 cycles/hour (365 cycles/day), for a gate of 15m
(equal to a cycle of 63%), (the control unit limits cycles
tothemaximumnumberspeciedintables2and3)**
Maximum time of continuous
operation (at nominal torque)
40 minutes (the control unit limits continuous operation
tothemaximumlimitsasspeciedintables2and3)***
60 minutes (the control unit limits continuous operation
tothemaximumlimitsasspeciedintables2and3)***
Operating limits IngeneralRUNisdesignedfortheautomationofgateswiththeweightsandlengthsasspecied
Durability Estimatedbetween150.000cyclesand450.000cyclesaccordingtoconditionsspeciedinTable4
Power: RUN 400HS - 1200HS
Versione V1
230VAC(+10%-15%)50Hz.
120Vac50/60Hz
Maximum power absorption on
start-up [corresponding to Amps]
510 W
(4,7 A)
550 W
(5,2 A)
Insulation class 1 (safety earthing required)
Flashing light output For 2 Flashing lights LUCYB (lamp 12V, 21W)
Gate open indicator output For 1 24V lamo of maximum 4W (output voltage may vary between -30 and +50% and can also control small
relays)
BLUEBUS output One output with a maximum load of 15 BlueBus units
STOP input Fornormallyclosedornormallyopencontacts,for8.2kΩconstantresistance;withself-recognition(anyvaria-
tionfromthememorizedstatuscausesthe“STOP”command)
Step-by-step input For normally open contacts (contact closure generates S.S. command)
OPEN input For normally open contacts (contact closure generates OPEN command)
CLOSE input For normally open contacts (contact closure generates the CLOSE command)
Radio connector SM connector for receivers SMXI; SMXIS or ONEXI
Radio ANTENNA input InputANTENNARadio52ΩforcabletypeRG58orsimilar
Programmable functions 8 ON-OFF type functions and 8 settable function (see tables 7 and 9)
Functions in self-learning mode Self-learning of devices connected to BlueBus output
Self-learningof“STOP”devicetype(contactNO,NCor8,2KΩresistance)
Self-learning of gate length and calculation of deceleration and partial opening points
Operating temperature -20°C ... 50°C
Protection rating IP 44
Dimensions and weight 400 x 255 h 390 mm; 24.5kg
* 12 tooth modulus 6 pinion available as option.
** At 50°C and with a gate of 15 metres, the maximum operating frequency is 7 cycles/hour (equal to a cycle of 40%).
*** At 50°C the maximum continuous operation time is 10 minutes.