Unit type
P
roduct description
VPL15 Top M2 is a ventilation unit that allows for active heat recovery via a high-efficiency heat pump.
The unit is intended for air volumes up to 400 m
3
/h at 100 Pa external duct pressure.
The unit extracts humid and vitiated air from the dwelling via bathroom, lavatory, kitchen and utility
room. It blows fresh air into living areas such as living room, bedrooms and study. Cold outdoor air is
heated in the heat exchanger by warm extract air. If the supply air/the dwelling needs heating, the heat
pump will heat up the supply air, depending on the room temperature. VPL15 Top M2 has a reversible
cooling circuit and it can therefore cool the supply air in the summer.
As a standard, VPL15 Top M2 is supplied with plate filters in outdoor air and extract air. If you want to
filter out pollen from the outdoor air, a pollen filter can be purchased as an accessory and be
retrofitted.
1. Duct connections
2
. Filter replacement door
3. Control panel
4. Outdoor air filter (if purchased as an accessory, a pollen filter should be fitted here)
5. Extract air filter
6. Extract air fan
7. Supply air fan
8. Automation
9. Heat pump
10. Condensate drain
11. 8-pole plug
6