EasyManuals Logo

Nilfisk-ALTO ATTIX 30 Quick Start Guide

Nilfisk-ALTO ATTIX 30
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
14
*)
Optional accessories / Model variants
ATTIX 30/40/50
EN
ES
FR
minimum cross-sections of the cable:
Cable length Cross section
< 16 A < 25 A
up to 20 m 1.5 mm
2
2.5 mm
2
20 to 50 m 2.5 mm
2
4.0 mm
2
Battery Charger
Only use the battery which is delivered with
the charger. Other types of batteries could
cause an explosion. Do not attempt to charge
alkaline batteries or other types of primary
batteries. Do not dispose of batteries in re as
the battery may explode, leak or catch re.
Keep the charger in a dry place (indoor use
only). In order to avoid the risk of re or elec-
trical shock, the charger must be protected
against high humidity and water.
The charger must
not be used if plug or cover are defective
not be opened or converted
kept away from children
not be used unattended
be disconnected after use
be cleaned with a soft cloth only after the
plug is disconnected
be repaired only by authorised personnel
Warranty
Our general conditions of business are ap-
plicable with regard to the guarantee.
Unauthorised modi cations to the appliance,
the use of incorrect brushes in addition to us-
ing the appliance in a way other than for the
intended purpose exempt the manufacturer
from any liability for the resulting damage.
Tests and approvals
Electrical tests must be per formed in accord-
ance with the provisions of safety regulations
(BGV A3) and to DIN VDE 0701 Part 1 and
Part 3. In ac cord ance with DIN VDE 0702
these tests must be performed at regular
intervals and after repairs or modi cations.
Risks
Electrical components
DANGER
Electric shock due to faulty mains
connecting lead.
Touching a faulty mains connect-
ing lead can result in serious or
even fatal injuries.
Do not damage the mains 1.
power lead (e.g. by driving over
it, pulling or crushing it).
Regularly check whether the 2.
power cord is damaged or
shows signs of ageing.
Have the faulty mains con-3.
necting lead replaced by your
Nil sk-Alto service representa-
tive or a quali ed electrician
prior to using the appliance
again.
DANGER
The upper section of the vacuum
cleaner contains live components.
Contact with live components leads
to serious or even fatal injuries.
Never spray water on to the 1.
upper section of the vacuum
cleaner.
CAUTION
Appliance socket
*)
.
The appliance socket is only
designed for the purposes de ned
in the operating instructions. The
connection of different appliances
can result in damage.
Prior to plugging in an appliance, 1.
always switch off the vacuum
cleaner and the appliance that is
to be connected.
Read the operating instructions 2.
to the appliance to be connected
and observe the safety notes
contained in these.

Other manuals for Nilfisk-ALTO ATTIX 30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-ALTO ATTIX 30 and is the answer not in the manual?

Nilfisk-ALTO ATTIX 30 Specifications

General IconGeneral
CategoryVacuum Cleaner
Tank Capacity30 l
Airflow3700 l/min
Vacuum Pressure250 mbar
Hose Length2.5 m
Dimensions450 x 380 x 595 mm
ModelATTIX 30
Mains connection230 V, 50-60 Hz
Cable Length7.5 m