TROUBLE-SHOOTING
Fault Cause Remedy
Motor does not run
Reduced suction power
> Mains plug not plugged in
> Circuit breaker of connection
outlet has been tripped
> Circuit breaker tripped due to
wrong rotating field
> Overcurrent protection or
temperature monitoring unit
has been triggered
> Automatic mode only:
- Contact loop of automatic
system not closed
> Suction nozzle blocked
> Suction hose blocked
> Filter cartridge dirty
> Exhaust-air flap of stopped
turbine jammed
Plug mains plug into outlet
Reset circuit breaker
See section Electrical connec-
tion
See section Continuously lit
fault lamp.If overcurrent
protection or temperature
monitoring unit triggers
repeatedly, inform Wap
Customer Service
Check contact loop(s) or
contact points
Clean suction nozzle
Clean suction hose
Replace filter element.See
Section Changing filter
element.
See Section Checking
exhaust-air flap.