C391
12
09/2014
VHW310 - VHW311
GB
Troubleshooting
Problem Cause Remedy
The vacuum cleaner suddenly stops
Clogged primary lter
Shake the lter. Replace it if this is not
sufcient.
Clogged vacuum hose Check the vacuum hose and clean it.
Circuit breaker activation
Check the setting.
Check the motor electrical input.
Empty the container.
Contact an authorised after-sales
service centre if necessary.
Dust leaks from the vacuum cleaner The lter is torn
Replace it with another of identical
type.
Electrostatic current on the vacuum
cleaner
Non existent or inefcient grounding
Check all ground connections.
Especially check the connection at the
inlet.