- 25 -
Trouble Shooting Guide
Emergencies
Gas leaking from
cracked/cut/burned hose
Possible cause Prevention/Solution
Damaged hose
Turn off gas at LP tank, if hoes
is out or cracked. replace hose.
See LP tank lead test and
connection regulator to the LP
Gas lea king from
LP tank
Mechanical failure due
to resting or mishandling
Turn off LP tank valve
Gas leaking front
LP tank valve
Failure or tank valve
from mishandling or
mechanical failure
Turn off LP tank valve.
Return LP tank to gas supplier
Gas leaking between
LP tank and regulator
connection
Improper installation,
untight connection,
failure of rubber seal
Turn off LP tank valve.
remove regulator from cylinder
and visually inspect rubber seal
for damage, see LP tank test
and connection regulator to
the LP tank
Fire coming through
control panel
Fire in burner tube
section of burner due
to partial blockag
Turn off control knobs and
LP tank valve.
After fire is out and grill is cold,
remove burner and inspect for
spider nests or rust. see natural
hazard and cleaning the burner
assembly pages