WARNING:
DO NOT USE THE GRILL if you cannot stop the leaks. Be sure the LP cylinder
valve is closed. If the LP cylinder is still leaking, contact your LP dealer or call 911.
Do not use any matches, open flames or smoke during leak testing.
Do not light any burners during leak testing.
Replacement parts, including a replacement hose assembly, must be as specified in
the parts list.
OPERATING INSTRUCTIONS
Always visually inspect your grill before lighting. Replace any hose that are frayed or cracked.
Look for anything that could block spaces for ventilation and remove it or more the grill.
After lighting, check the flame pattern to ensure you have even heat distribution for each
burner. If burners won't light, or if the flame pattern is uneven, see the Troubleshooting section.
- 19 -
Ensure the LP cylinder valve and all burners are “OFF”.
Ensure the LP cylinder is connected to the regulator.
If the warnings in 1 and 2 above are not followed exactly, a fire causing death or
serious injury may occur.
Mixing water and liquid dish detergent IS needed. Do not use any household cleaner solution.
Open the LP tank valve by turning the hand wheel counterclockwise one turn. If you
hear a rushing sound, tuRN the gas off immediately. In that case, there could be a
leak at the connection.
Reconnect the cylinder to the regulator.
Spray or brush on the dish detergent solution covering the following areas: regulator
and cylinder connection, gas hose connections to the regulator, all gas hoses, and all
gas connections to the burner, including the side burner.
Bubbles that develop on any of the parts and connections listed above indicate a gas leak.
Immediately shut off the LP tank valve by turning the valve clockwise. Retighten the
connections or order replacement parts as needed. Continue to test as necessary
until no leaks are detected.
Close the LP tank valve by turning the hand wheel clockwise.
1.
2.
3.
4.
5.
6.
7.
8.
LEAK TESTING FOR REGULATOR, VALVES, HOSES, AND COHHEGTIDNS