SWR/POWER METER USER MANUAL
Model : RS-101, RS-102, RS-402, RS-502
INTRODUCTION:
This SWR & POWER meter is a highly accurate RF meter for measuring Forward Power,
Reversed Power, & VSWR.
Main Features:
1. Large meter display for ease of reading.
2. Forward RF power readings (switchable to indicate either average power or Peak Envelope Power [PEP],
for SSB and AM transmitters),
3. Reversed RF power readings.
4. VSWR rations.
5. Illuminated meter.
6. Convenient control layout for ease operation.
SPECIFICATIONS:
MODEL RS-101 RS-102 RS-402 RS-502
Frequency Range 1.6 - 60 MHz 1.8 - 200 MHz 125 - 525 MHz 1.8 - 525 MHz
Power Range
0 - 3 KW
Power Scale
30/300/3KW
Maximum Power
3 KW
Accuracy : LOW power
Accuracy : HIGH power
Minimum Power for SWR
Input/Output Impedance
Input/Output Connectors
Insertion Loss
Testing Function
Dimension (W/H/D) mm
Weight (Net) 780 g 790 g 800 g 950 g
Accessories
<FRONT PANEL>
<FRONT & REAR PANEL>
1. Meter Display : Indicates FWD/REV power in watts and VSWR ratio
2. Function Switch : Select FWD/REV power, Calibration, and VSWR.
3. Range Switch : Selects RF power range of 5/20/200W, 30/300/3KW.
4. Calibration Knob : Sets full scale deflection when measuring VSWR
5. AVG/PEP MONI.(Push button) : Selects AVG or PEP RF power readings.
6. Meter Zero Adj.: Mechanical adjustment for meter needle.
<REAR PANEL>
7. TX Connector : Coax connector to transmitter 50 ohm RF output.
8. ANT Connector : Coax connector to 50 ohm antennna system.
9. 13.8V DC connection (via power supply) for meter LED illumination.
10. HF/VUHF band switch : available on RS-502 only.
11& 12. 2nd pair of TX/ANT connector : available on RS-502 only.
0 - 200 W
5/20/200W
200W
(AVG) +/- 10%, (PEP) +/- 15%
(AVG) +/- 5%, (PEP) +/- 10%
1 W
190 x 85 x 135 mm
Operation Manual, 13.8 DC Wire
50 OHM
"M" or/and "N" type
Less than 0.1 dB
Fwd/Rev Power, PEP, SWR
Question and Answer IconNeed help?

Do you have a question about the Nissei RS-101 and is the answer not in the manual?

Nissei RS-101 Specifications

General IconGeneral
BrandNissei
ModelRS-101
CategoryMeasuring Instruments
LanguageEnglish

Summary

Introduction to SWR/Power Meter

Key Features of SWR/Power Meter

SWR/Power Meter Technical Specifications

Installation Guide

Forward Power Measurement

Measure forward RF power. Select FWD function and appropriate range. AVG/PEP button selects mode.

Operation and Measurement Procedures

Reverse Power Measurement

Measure reverse power on the coaxial cable. Settings similar to forward power measurement.

VSWR Measurement

Measure VSWR ratio. Set to CAL, adjust knob to full scale, then switch to SWR.