Nissei RS-40 SWR_POWER METER USER MANUAL
Main features :
RS-40 SWR&POWER meter can read out directly without any calibration.
RS-40's maximum measurable power range up to 200W.
Low insertion loss structure allows it to be connected permanently.
1. Output power measurement
(1) Set the function switch to PWR position
(2) Set the power range switch to appropriate power range corresponding to the power of your
radio equipment
(3) Set the radio equipment on transmit and read out a scale corresponding to the range.
(High:200W, Mideum:60W, Low:15W)
2. SWR measurement
(1) Measure output power as described in the section 1.
(2) Power range switch remain unchanged, set the function switch to SWR position.
(3) Set the radio equipment on transmit mode, and figure out SWR by reading out cross section
of the extension point of auxiliary scale at the right end which is corresponding to the
power reading indicated in section 1 and meter indicator reading. (High range..., Medium
range...,Low range....)
Specifications
Frequency range 140-150MHz, 430-450MHz
Measurable power range 0 - 200W
Power range 15W, 60W, 200W
Insertion loss 0.3 dB or lower
Impedance 50 ohm
Dimension 70W x 78H x 30D mm
Weight 180 g
Connector MJ - MJ (BNC, N optional)
Note:
1.Since the meter movement is very sensitive, avoid excessive vibration or mechanical shock .
2.The absolute maximum power that should be applied to the meter is 200W. Also observe
maximum power inputs of 15W and 60W when using the two lower ranges.
3.The meter must never be reverse connected. Always observe the correct connections to
transmitter and antenna as indicated on the rear sockets.
4.The meter has been carefully calibrated at the factory. Tampering with any of the internal
circuitry or sensors may cause damage and will degrade the meter's accuracy.
5.Do not expose the meter to excessive temperatures, high humidity, or strong magnetic fields.
Source: https://well.com.sg/meters/nissei-200w-swrwattmeter-125-525-mhz.html
Question and Answer IconNeed help?

Do you have a question about the Nissei RS-40 SWR-POWER and is the answer not in the manual?

Nissei RS-40 SWR-POWER Specifications

General IconGeneral
Impedance50Ω
ConnectorsSO-239
DisplayAnalog meter
Accuracy±10%
Power SupplyNot required
Dimensions155 x 63 x 103 mm

Summary

Nissei RS-40 SWR Power Meter Overview

Key Features

Device offers direct readout without calibration, max power up to 200W, and low insertion loss for permanent connection.

Operating Procedures

Output Power Measurement

Steps to measure output power: set function to PWR, select range, transmit radio, and read scale.

SWR Measurement

Steps to measure SWR: perform power measurement, set function to SWR, transmit, and read auxiliary scale.

Technical Specifications

Important Notes and Safety

Handling and Usage Precautions

Avoid shock, observe max power limits (200W, 15W/60W ranges), ensure correct connection, and avoid environmental extremes.

Related product manuals