EasyManua.ls Logo

Nobel FCD 05 User Manual

Default Icon
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
rev. 4
Page 1 of 23 fcd-dp_mi-r4.doc
AUTOMATIC FILTERS
FCD/DT
FACD/DT
FFD/DT
FCD/DP
FACD/DP
FFD/DP
FCD/DT-DUAL
FACD/DT-DUAL
FFD/DT-DUAL
FCD/DP-DUAL
FACD/DP-DUAL
FFD/DP-DUAL
INSTRUCTIONS MANUAL
WARNING!
The equipment must be used only for the utilization for which they have been
designed, as shown in the technical documentation.
Read carefully this leaflet until the end before starting any operation.
Proceed strictly according to all directions included in this manual.
Automatic filters series FCD, FACD and FFD are designed to treat raw water supplied
from municipalities or from well.
ANY OTHER APPLICATIONS OF THE EQUIPMENT DIFFERENT THAN THE MENTIONED
ONES IS MADE UNDER THE ONLY RESPONSIBILITY OF THE USER.
For any assistance concerning the installations, maintenance or utilization of the equipment
apply the NOBEL Service Center closest to you or directly :
NOBEL S.r.l. via Monfalcone 8 – I-20132 Milano
tel. +39 02 2827968 fax +39 02 2610839
Question and Answer IconNeed help?

Do you have a question about the Nobel FCD 05 and is the answer not in the manual?

Nobel FCD 05 Specifications

General IconGeneral
BrandNobel
ModelFCD 05
CategoryWater Filtration Systems
LanguageEnglish

Summary

Safety Guidelines

Principles of Operation

Quartz-Sand Filters (FCD)

Explains the mechanical filtration process using quartz sand and backwashing.

Activated-Carbon Filters (FACD)

Details the process for removing organic matters and chlorine with activated carbon.

Technical Characteristics

Iron Removal Filters (FFD)

Describes the filtration process for removing iron and manganese using catalytic media.

Installation Procedures

Connections and Media Loading

Hydraulic Connections

Details on connecting water lines, drain, air supply, and solenoid valves.

Loading the Filter Media

Step-by-step guide for loading different types of filter media into the vessel.

Electrical Wiring Connections

End Cycle and Regeneration

Regeneration Triggers

Methods for initiating regeneration: time-based and pressure-drop-based.

Regeneration Process Details

Details manual and automatic regeneration cycles, including warnings.

Regeneration and Supply Control

Control Panel Operation

Logical Programmer Functions

Overview of the LOGO programmer, inputs, outputs, and parameters.

System Settings

Starting Up the Unit

Service and Maintenance

Troubleshooting Guide