Noby-448 Installation & Programming Instructions (Rev.5) Page 1 of 12
Fire Control Panel
Installation & Programming Manual
TABLE OF CONTENTS
Page
Getting Started
2
Power Supply Unit
3
Remote Keypad Bus
3
Inputs & Outputs
4
User Keypad Functions
5
Engineer Keypad Functions
6
Troubleshooting
7
Specification
9
LED Indications
10
Connection Diagram
11
Keypad Function Chart
12
Question and Answer IconNeed help?

Do you have a question about the Noby 448 and is the answer not in the manual?

Noby 448 Specifications

General IconGeneral
BrandNoby
Model448
CategoryControl Panel
LanguageEnglish

Summary

Getting Started

Power-Up With Battery

Instructions for powering up the panel using a battery supply.

Power-Up With Mains

Instructions for powering up the panel using the mains power supply.

Installing the Noby-448XT 4-Zone Extender Card (Optional)

Guide for installing the optional 4-Zone Extender Card and its configuration.

Power Supply

Power Supply Unit

Details on the PSU's regulators, current ratings, and battery charging capabilities.

Remote Keypad Bus

Remote Keypad Bus

Information on connecting and configuring up to three external Noby-448RKP keypads.

Inputs and Outputs

Zone Detector Circuits

Requirements for terminating detector zones with EOL resistors for monitoring.

Class Change Input (Bell Ring)

Describes the positive going input signal for switching sounders directly.

Fault Input

Input signal for ancillary equipment to trigger common fault indication.

Sounder Circuits

Details on conventional sounder circuits and EOL resistor monitoring.

Fire Relay Output

Description of the double pole voltage-free fire relay contacts activated on fire detection.

Panel Sounder (Piezo)

Information on the piezo sounder at remote keypads and main PCB for fault warnings.

Auxiliary Supplies (Aux 12v, Aux 24v)

Details on the 12v and 24v auxiliary supplies, including fuses and monitoring.

Communication Port (JP1)

Description of zonal outputs, fault output, and system common ground on JP1.

User Keypad Functions

General User Functions

Overview of accessing functions with the Access Code and auto-revert.

Mute Sounders and Panel

Instructions to switch off main external and panel internal sounders.

System Reset and Quick Reset

Procedures for resetting the system, including LED tests and quick reset.

Evacuate Function

Activates external/internal sounders and the Fire Alarm Relay for evacuation.

Zone and Relay Isolation

Function to isolate zones or the Fire Alarm Relay and check isolation status.

System Test Function

Function for 'one-man' system testing of detectors and zones.

Engineer Keypad Functions

General Engineer Functions

Overview of accessing engineer functions and the system's auto-revert feature.

Sounder Isolation and Event Log

Isolating sounders and recalling the last 8 event log entries.

Configuration Options

Options to configure extender, fault input polarity, latching zone faults, and test reminders.

Non-Latching Zones and Fault ID

Programming non-latching zones and identifying sounder circuit faults.

Troubleshooting

Power Supply Troubleshooting

Troubleshooting for power supply issues, including LED indications and fuses.

Zone Fault Troubleshooting

Troubleshooting for zone fault LEDs: continuous, flashing, and intermittent indications.

Sounder Fault Troubleshooting

Troubleshooting for sounder fault LEDs and circuit wiring issues.

Zones 5 to 8 Issues

Troubleshooting for zones 5-8, related to the Noby-448XT module or configuration.

Fault Indications and Operation

CPU and Common Fault Indications

Explains CPU and Common Fault LED indications and their troubleshooting.

Alarm Relay and User Keypad Operation

Checks on alarm relay functionality and user keypad operation issues.

Remote Keypad and Diagnostic Tool

Troubleshooting remote keypads and using the diagnostic tool with disable switches.

Noby-448 Specification

Power Supply Unit Specifications

Technical specifications for the Power Supply Unit, including voltage and current ratings.

Standby Battery and Voltage Monitoring

Specifications for standby battery current, voltage monitoring, and capacity test.

Zone Circuit Specifications

Technical specifications for detection zones, EOL resistors, and monitoring parameters.

Sounder Circuit Specifications

Technical specifications for sounder circuits, including maximum sounders per circuit.

Fire Alarm Relay Specification

Specification for the Fire Alarm DPDT Relay's contact rating.

Technical Data and Indicators

Communication Port and Signal Inputs

Specifications for Communication Port (JP1) and Signal Inputs.

Cabinet Specifications

Dimensions and shipping weight for the main panel and remote keypads.

LED Indications Reference

Description of continuous and flashing states for all panel LEDs.

Connection Diagram

Keypad Functions Summary

User Keypad Functions Summary

Summary of user-accessible keypad functions with their respective access codes.

Engineer Keypad Functions Summary

Summary of engineer-accessible keypad functions with their respective access codes.