Extension Cords. Using an improper extension cord
could result in re and electrical shock which may result in
injury, death or damage to device and property. If extension
cord must be used, make sure that: (1) The pins on the
extension cord plug have the same number, size, and shape
as those of the AC power cord plug on the charger; (2) The
extension cord is properly wired and is in good condition; (3)
The wire size is as specied in Table 1 below.
Recommended Minimum AWG Size For
Extension Cords For Battery Chargers
AC Input Rating,
Amperes*
Equal To
Or Greater
Than
But Less
Than
25
(7.6)
0
2
3
4
5
6
8
10
12
14
16
18
18
18
18
18
18
18
18
16
16
16
14
14
18
16
16
14
14
12
12
10
10
10
8
8
2
3
4
5
6
8
10
12
14
16
18
20
18
18
18
18
16
16
14
14
12
12
12
12
16
14
14
12
12
10
10
8
8
8
8
6
100
(30.5)
50
(15.2)
150
(45.6)
AWG Size of Cord
Length Of Cord, Feet (m)
*If the input rating of a charger is given in watts rather
than amperes, the corresponding ampere rating is to
be determined by dividing the wattage rating by the
voltage rating - for example:
1250W
+
125V = 10 Amperes