G3500 3.5A (3500mA)
6V & 12V Multi-Purpose Battery Charger
WHAT’S IN THE BOX
•G3500 Charger
•Battery Clamp Connectors
•Eyelet Terminal Connectors
•Owner’s Manual & User Guide
CHARGING STEPS
Step 1: Diagnostics
Checks the battery voltage to make sure battery connections are good and the battery is in a stable condition before beginning the charge process.
Step 2: Recovery
Initializes the Recovery process, if needed, for deeply discharged or sulfated (desulfation) batteries by pulsing small amounts of current.
Step 3: Soft Start
Begins Bulk charging process with a gentle (soft) charge.
Step 4-5: Bulk
The Bulk charging process continues using both a High Rate and Medium Rate charge and returns 80% of battery capacity, indicated by the 25%, 50% and 75%
CHARGE LEDs.
Step 6: Absorption
Brings the charge level to 90%. The battery charger will deliver small amounts of current to provide a safe, ecient charge and limit battery gassing.
Step 7: Trickle
Battery is fully charged and ready to use, indicated by the 100% CHARGE LED being a solid Green. In this step, the battery charger will only deliver enough current to
keep the battery full. If the battery tells the charger that more current is needed, the battery charger will switch to Maintenance.
Step 8: Maintenance
Continuously monitors the battery voltage to determine if a maintenance charge should be initiated. If the terminal voltage falls below 6.4V (6V) and 12.8V (12V),
the charger will start the Maintenance cycle until voltage reaches 7.2V (6V) and 14.4V (12V) and then discontinues the charge cycle. The cycle between Trickle and
Maintenance is repeated indenitely to keep the battery at full charge, without overcharging. The battery charger can be left connected indenitely.
CHARGING TIMES
The time required for the G3500 to charge a normally discharged battery is shown below. Deeply
discharged batteries may take longer to charge depending on the depth of discharge (DOD). The
charge time is based on an average depth of discharge to a fully charged battery.
Note: The above table is for reference purposes
only. Actual data may dier due to battery
conditions. The time required for the G750 to
charge a normally discharged battery is based
on an average DOD of 50%
G3500 TECHNICAL SPECIFICATIONS
Input Voltage 200-240V, 50-60Hz
Eciency ~85%
Power 60W (Max)
Charging Current 1.1A
Low Voltage Detection 2V
Back Current Drain <5mA
Temperature Range 0ºC to 40ºC
Charger Type: 8-Step Smart Charger
Battery Types 6V & 12V
Battery Chemistries Wet, Gel, MF, CA, EFB, AGM and LIB
Battery Capacities 2-120Ah
Housing Protection IP65
Cooling Natural Convection