26MHz Clk-frequency at C830 
 
 
 
 
 
 
 
In case that CCONT N100 seems to be the responsible for not power on, check VB 3.6VDC at C129. 
Check 32.768kHz square wave at J228. 
Check that PWRONX decreases to 0V at S330 when pressing the power switch. Also check R118. 
If these conditions are fulfilled, output voltage lines must rise to their supposed values and PURX is 
released after some milliseconds by CCONT: 
VBB 2.8VDC at C107 
VCORE 1.8VDC at C140 
VXO 2.8 VDC at C152 
If one of these voltages is not measurable CCONT is faulty in all probability. 
Swap the phone because CCONT is underfilled and therefore not changeable. 
 
Also responsible for this fault could be the MAD D200. In this case check 32.768kHz square wave at 
J228. 
Check 13MHz Clk-frequency at C213. 
Check following voltages: 
VBB 2.8VDC at C201 
VCORE 1.8VDC at C140 
SLEEPX 2.8VDC at J226 
PURX 2.8VDC at J2327 
If all above mentioned works but the phone does not switch on, MAD is faulty in all probability. 
Swap the phone because MAD is underfilled and therefore not changeable.
 
 
 
 
 
 
 
 
13MHz Clk-frequency at C213