EasyManua.ls Logo

Nokia 7705 SAR-Hm - 2.15 Hazardous Locations

Nokia 7705 SAR-Hm
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SAR-Hm and SAR-Hmc Chassis Installation Guide Mandatory Regulations
3HE 17810 AAAA TQZZA © 2022 Nokia. Nokia Confidential Information
Use subject to agreed restrictions on disclosure and use.
57
2.15 Hazardous Locations
2.15.1 Chassis Labels
The 7705 SAR-Hm and 7705 SAR-Hmc chassis display the following labels:
2.15.2 Conditions of Use
The equipment shall be installed in an enclosure that provides a degree of
protection not less than IP 54 in accordance with EN 60079-0 and EN 60079-7.
Any field wiring connections or cable entries used for this outer enclosure shall
also be suitably certified against the enclosure requirements of EN 60079-0 and
EN 60079-7. The installer shall ensure that the maximum ambient temperature
of the module when installed is not exceeded.
The equipment shall only be used in an area of at least pollution degree 2, as
defined in IEC 60664-1.
The chassis shall be grounded as described in the in this manual before use.
The SIM card shall be connected or disconnected only in a non-hazardous area
or when the device is not energized.
The end-use enclosure shall provide a Warning label “Do not open while
energized”.
Note: See 7705 Outdoor Enclosure Requirements for Hazardous Locations for hazardous
locations requirements pertaining to the 7705 Outdoor Enclosure.

Table of Contents