EasyManua.ls Logo

Nokia FastMile 2.1.04 - Other Environmental Requirements; Environmental Requirements; Storage; Transportation

Nokia FastMile 2.1.04
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ETSI environmental and CRoHS guidelines
20
Nokia FastMile 4G Gateway Product Overview
3TG-00743-ABEA-TCZZA Issue: 02
2.3 Other environmental requirements
Observe the following environmental requirements when handling the Nokia
FastMile 4G Gateway.
2.3.1 Environmental requirements
See section 2.3.5 for thermal limitations and see chapter 15 for information about
temperature ranges for the Nokia FastMile 4G Gateway and other Nokia FastMile 4G
Gateway specifications.
2.3.2 Storage
According to ETS 300-019-1-1 - Class 1.1, storage of the Nokia FastMile 4G
Gateway must be in Class 1.1, weather-protected, temperature-controlled locations.
2.3.3 Transportation
According to EN 300-019-1-2 - Class 2.3, transportation of the Nokia FastMile 4G
Gateway must be in packed, public transportation.
2.3.4 Stationary use
According to EN 300-019-1-3 - Class 3.1/3.2/3.E, stationary use of the Nokia
FastMile 4G Gateway must be in a temperature-controlled location with no
condensation allowed.
2.3.5 Thermal limitations
The thermal limitations for the Nokia FastMile 4G Gateway are:
operating temperature (ambient): 0°C to 40°C (32°F to 104°F)
storage temperature (ambient): -40°C to 70°C (-40°F to 158°F)
operating relative humidity: 5% to 85% relative humidity, non-condensing
short-term relative humidity: 5% to 93% relative humidity, non-condensing

Table of Contents

Related product manuals