NHL-10
Baseband Troubleshooting CCS Technical Documentation
ISSUE 2 01/2004 COMPANY CONFIDENTIAL 47
Copyright © 2003 Nokia. All Rights Reserved.
Table 2: Calibration value limit
Zocus (IBAT) calibration with MJ-2 module jig
Zocus (IBAT) calibration can be performed manually with module jig instead of JBV-1.
Connections
The NHL-10 phone must be placed in MJ-2 (Module jig). Two external power supplies and an
ammeter are needed.
• Supply 3.7-4.0 V DC from external power supply to module jig.
Phoenix Setup
• Start Phoenix service software.
• Select FBUS connection.
•Choose Main -> Choose product-> NHL-10.
•Choose Tuning -> Zocus EM.
Parameter Min. Max.
ADC Gain 25400 29000
ADC Offset -50 50
BSI Gain 970 1100
VBAT Gain 10000 11000
VBAT Offset 2300 2900
VCHAR 58000 62000
ICHAR 4050 4800
IBAT GAIN 0 255