RH-18/36/38  Company confidential
Engine module CCS Technical Documentation
Page 26  Nokia Corporation. Issue 1 10/03
Test Interfaces
The test pattern is placed on engine PWB, for service and production purposes, same test 
pattern is used for after sales purposes as well.
Through MBUS or FBUS connections, the phone HW can be tested by PC software (Phoe-
nix) and production equipment (FLALI/FINUI/LABEL). 
The test points are listed in the schematic diagrams
Connections to Baseband
The flash programming box, FPS8, is connected to the baseband using a galvanic connec-
tor or test pads for galvanic connection.
The flash programming interface connects the flash prommer to the UPP via the UEM 
and the connections correspond to a logic level of 2.7 V. The flash prommer is connected 
to the UEM via the MBUS (bi-directional line), FBUS_TX, and FBUS_RX. The programming 
interface connections between the UEM and the UPP constitute the MBUS_TX, 
MBUS_RX, FBUS_TX, and FBUS_RX lines. The interface also uses the BSI 
(Battery_Size_Indicator). 
FBUS Interface
FBUS is an asynchronous data bus having separate TX and RX signals. Default bit rate of 
the bus is 115.2 kbit/s. FBUS is mainly used for controlling phone when flashing.
MBUS Interface
MBUS interface is used for controlling the phone in service. It is bi-directional serial bus 
between the phone and PC. The default transmission speed is 9.6 kbit/s.