Table of Contents
1 INTRODUCTION ................................................................................................... 1
2 DEVICE CONFIGURATIONS .............................................................................. 1
2.1 M2000 DESKTOP .................................................................................. 1
2.2 M2000 SLIMLINE .................................................................................. 2
2.3 M2000
NEMA ..................................................................................... 2
2.4 O
NBOARD WEIGH CENTER ................................................................... 3
2.5 ONBOARD COMPACT WEIGH CENTER .................................................. 4
3 GENERAL OPERATION ...................................................................................... 6
3.1 KEYPAD FUNCTIONS KEYS ................................................................... 6
3.1.1 On/Off Key ................................................................................... 6
3.1.2 ZERO Key .................................................................................... 7
3.1.3 TARE Key ..................................................................................... 7
3.1.4 CLEAR Key .................................................................................. 7
3.1.5 PRINT SELECT Key .................................................................... 7
3.2 S
PECIAL KEYPAD FUNCTIONS ............................................................... 8
3.2.1 Selecting scale channels ............................................................... 8
3.2.2 Summing channels in TOTAL mode ............................................. 8
3.2.3 Scan mode .................................................................................... 9
3.2.4 Gross/Net ..................................................................................... 9
3.2.5 Pound/Kilograms selection .......................................................... 9
3.2.6 TEST display ................................................................................ 9
4 APPLICATION PARAMETER SETTINGS ...................................................... 10
4.1 ONBOARD SCALE SETINGS ................................................................. 10
4.2 MULTIPLE ANIMAL SCALE SETTINGS ................................................. 12
5 CALIBRATION AND SEALING ........................................................................ 13
5.1 PLACING THE INDICATOR INTO CALIBRATION MODE .......................... 13
5.1.1 Special Keypad function keys during calibration ....................... 13
5.1.1.1 Selecting a calibration parameter. .......................................... 13
5.1.1.2 Editing a calibration parameter. ............................................. 13
5.1.1.3 Canceling a calibration parameter. ......................................... 14
5.1.1.4 Toggle between weight and AD counts. ................................ 14
5.1.1.5 Exiting Calibration Mode. ...................................................... 14
5.2 C
ALIBRATING WITH WEIGHTS ............................................................ 15
5.2.1 Set the Scale Parameters ............................................................ 15
5.2.2 Balance the Scale ....................................................................... 15
5.2.3 Deadloading the Scale (scale zero) ............................................ 22
5.2.4 Spanning the indicator ............................................................... 22
5.3 S
EALING THE INDICATOR .................................................................... 22
5.3.1 Electronic Seal ........................................................................... 22
5.3.2 Audit Trail .................................................................................. 22
5.3.3 Accessing the Audit Trail ........................................................... 23
6 WEIGH CENTER CIRCUIT BOARD ................................................................ 24