5
Table1:SystemSpecifications
SupplyVoltage(rated) 12VDC
SupplyCurrent(rated) 10A
HydraulicPressure(maximum) 3300psi
BaudRate 250kbps
ClockFrequency(maximum) 96MHz
SolenoidValvePWMFrequency 300Hz
UltrasonicSensorTransmitFrequency 50kHz
OperatingTemperatureRange 0°Cto80°C
The10Afuseonthepowercablemaybereplacedbytheoperatorifneeded.Thereplacementfusemust
beratedtoblowinlessthan120secondsat200%andbeANSI/UL24814orbetter.
Table2:ReplacementFuse
NORACPartNumber 106676
ManufacturerPartNumber Littelfuse0287010.PXCN
TheUC5™productlineiscoveredbymultiplePatentsincluding,butnotlimitedtothefollowing:
U.S.Pat.No:US200415838,US88432831
EuropeanPat.No:EP1444894,EP2630856
CanadianPat.No:CA2418610