How to fix NORBIT WINGHEAD Industrial Equipment when sonar is connected but no INS data is received?
- Wwilliam10Aug 22, 2025
If the NORBIT Industrial Equipment sonar is connected but no INS data is being received, try the following: * Disable Windows Firewall, or allow NORBIT GUI access and add an exception for UDP port 5602. * Open Windows Command Prompt and type `ping 192.168.53.100` to check if the INS is detectable. * Check network configuration to ensure the computer IP address doesn't conflict with the INS IP address (192.168.53.100). * Check cable connections and re-seat if necessary. * Check for bent sonar cable pins. * Check for a possible IP address conflict in network settings. * Ground SIU. * Go to INS Tools > INS Setup Wizard and select Factory to restore default settings. * Perform the “resistance test” to check status of circuit components. Refer to Appendix for pinout diagrams.