4
www.norcold.com
DE105
Internal Capacity
Total capacity -------------------------------------------------------------------------------------------------3.7 cubic feet
Controls
ON/OFF/TEMP SET switch ------------------------------------------------------------------------------------Manual
Temperature setting range ----------------------------------------------------------0=OFF, 1=cold to 5=coldest
Temperature sensing devices ------------------------------------------------------------- Capillary Tube Sensor
Off-level Operating Limits
Side-to-side ------------------------------------------------------------------30 degrees maximum at refrigerator
Front-to-back ----------------------------------------------------------------30 degrees maximum at refrigerator
DC Power
Electronic controls voltage requirements ----------------------------------------------------- 12 VDC / 24 VDC
Minimum ----------------------------------------------------------------------------------------- 10.9 VDC / 22.7 VDC
Maximum ---------------------------------------------------------------------------------------- 22.7 VDC / 31.5 VDC
Fuse / Breaker ---------------------------------------------------------------------------------------------- 15 A / 15 A
AC Power
Electronic controls voltage requirements -----------------------------------------------------------------120 VAC
Minimum --------------------------------------------------------------------------------------------108 VAC (59 Hertz)
Maximum ------------------------------------------------------------------------------------------- 132 VAC (61 hertz)
Fuse / Breaker --------------------------------------------------------------------------------------------------------- 3 A
Typical DC Amperage Draw @ Nominal 12 VDC
Startup --------------------------------------------------------------------------------------------------------5.5 A / 2.7 A
Stabilization at 70
0
Ambient ------------------------------------------------------------------------------3.6 A / 1.8 A
Typical AC Amperage Draw @ Nominal 120 VAC / 240 VAC
Stabilization at 70
0
Ambient --------------------------------------------------------------------------- 0.75A / 0.47 A