EasyManuals Logo

Norcold NR751 Series User Manual

Norcold NR751 Series
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
Refrigerator Service Manual / Manuel d'entretien du réfrigérateur / Manual de servicio del refrigerador
6
NR740, 751 Models / Modèles NR740, 751 / Modelos NR740, 751
Internal Capacities
Total capacity
NR740 ---------------------------------------------------------------------------------------------- 1.5 cubic feet
NR751 ---------------------------------------------------------------------------------------------- 2.4 cubic feet
Controls
ON/OFF/TEMP SET switches ------------------------------------------------------------------------ Manual
Temperature setting range ------------------------------------------------- 0=OFF, 1=cold to 5=coldest
Temperature sensing devices -----------------------------------------------------Capillary Tube Sensor
Off-level Operating Limits
Side-to-side-----------------------------------------------------------30 degrees maximum at refrigerator
Front-to-back ---------------------------------------------------------30 degrees maximum at refrigerator
DC Power
Electronic controls voltage requirements -------------------------------------------- 12.8 VDC/24 VDC
Minimum (cut-out) ----------------------------------------------------------------------------VDC 10.5 / 22.8
Restart (cut-in) ------------------------------------------------------------------------------- VDC 11.8V / 24.2
Maximum---------------------------------------------------------------------------------17.0 VDC / 31.5 VDC
Fuse/Breaker - 12 VDC ------------------------------------------------------------------------------------ 15 A
Fuse/Breaker - 24 VDC ------------------------------------------------------------------------------------7.5 A
Wires and Receptacles - 12/24 VAC -------------------------------------------------------------------- 15 A
AC Power
Electronic controls voltage requirements --------------------------------------------120 VAC/240 VAC
Nominal------------------------------------------------------------------------------------------------100 - 240 V
Minimum (cut-out) ------------------------------------------------------------------------------------------- 90 V
Maximum----------------------------------------------------------------------------------------------------- 264 V
Fuse/Breaker - 120 VAC ------------------------------------------------------------------------------------- 3 A
Fuse/Breaker - 240 VAC ------------------------------------------------------------------------------------- 3 A
Wires and Receptacles - 120/240 VAC ---------------------------------------------------------------- 15 A
Typical DC Amperage Draw @ Nominal 12 VDC
Startup ------------------------------------------------------------------------------------------------- 5.5A / 2.7 A
Stabilization at 70
0
Ambient ---------------------------------------------------------------------- 3.6A / 1.8 A
Typical AC Amperage Draw @ Nominal 120 VAC / 240VAC
Stabilization at 70
0
Ambient -------------------------------------------------------------------0.75A / 0.47 A
Speci cations

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Norcold NR751 Series and is the answer not in the manual?

Norcold NR751 Series Specifications

General IconGeneral
BrandNorcold
ModelNR751 Series
CategoryRefrigerator
LanguageEnglish

Related product manuals