EasyManua.ls Logo

Nord Drivesystems NORDAC FLEX SK 230E Series - Page 218

Nord Drivesystems NORDAC FLEX SK 230E Series
284 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NORDAC FLEX (SK 200E ... SK 235E)Users Manual for Frequency Inverters
218 BU 0200 en-3118
Pos: 61 1 /Anlei tung en/El ektr onik/FU und St art er/5 . P ara meter /P ara meter au fli stung (P 000 .. .)/P 700- P799 /Para meter P744 A usbaus tufe [S K 1x0E, SK 2xxE ] @ 2\mod_1346932209541_388.docx @ 43656 @ @ 1
P744
Configuration level
(Configuration level)
0000 ... FFFF (hex)
This parameter displays the special devices integrated in the FI. Display is in hexadecimal code
(SimpleBox, Bus System).
The display is in plain text when the ParameterBox is used.
High byte: Low byte:
Pos: 61 2 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 .. .)/P7 00-P7 99/Par amet er P744 Ausba ustuf e _Teil 2/ 2 [SK 2x xE] @ 9 \mod_1448455671379_388.docx @ 266910 @ @ 1
00
hex
Standard I/O (SK 205E)
01
hex
STO (SK 215E)
00
hex
No extension 02
hex
AS-i (SK 225E)
01
hex
Encoder 03
hex
STO and AS-i (SK 235E)
02
hex
Posicon 04
hex
Standard I/O (SK 200E)
03
hex
--- 05
hex
STO (SK 210E)
06
hex
AS-i (SK 220E)
07
hex
STO and AS-i (SK 230E)
Pos: 61 3 /Anlei tung en/El ektr onik/FU und St art er/5 . Par amet er/ Par amet erau fli st ung (P 000 .. .)/P 700- P799 /Par amet er P747 Umrichterspannungsbereich [SK 1x0E, SK 2xxE, SK 2xxE-FDS] @ 9\mod_1448457030116_388.docx @ 266976 @ @ 1
P747 Inverter Volt. Range
(Inverter voltage range)
0 ... 2
Indicates the mains voltage range for which this device is specified.
0 = 100...120V
1 = 200...240V
2 = 380...480V
Pos: 61 4 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 ...) /P7 00-P7 99/Par amet er P748 Status CANopen [SK 1x0E, SK 2xxE] @ 2\mod_1346932210180_388.docx @ 43680 @ @ 1
P748
CANopen status
(CANopen status (system bus status))
0000 ... FFFF (hex)
or
0 ... 65535 (dec)
Shows the status of the system bus.
Bit 0:
Bit 1:
Bit 2:
Bit 3:
Bit 4:
Bit 5:
Bit 6:
Bit 7:
Bit 8:
Bit 9:
Bit 10:
24V Bus supply voltage
CANbus in "Bus Warning" status
CANbus in "Bus Off" status
System bus Bus module online (field bus module, e.g.: SK xU4-PBR)
System bus Additional module 1 online (I/O - module, e.g.: SK xU4-IOE)
System bus Additional module 2 online (I/O - module, e.g.: SK xU4-IOE)
The protocol of the CAN module is 0 = CAN / 1 = CANopen
Vacant
"Bootup Message" sent
CANopen NMT State
CANopen NMT State
CANopen NMT State Bit 10 Bit 9
Stopped
Pre- Operational
Operational
0
0
1
0
1
0
Pos: 61 5 /Allg emein/ Allg emeing ültig e Mod ule/---------Sei tenumbr uch ko mpakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1

Table of Contents

Other manuals for Nord Drivesystems NORDAC FLEX SK 230E Series

Related product manuals