P741 [-01]
...
[-19]
PZD bus Out
(Process data Bus Out)
S
0000 ... FFFF (hex)
information about the actual
status word and the actual
values that are transferred
via the bus systems.
Standardisation:
( section 8.9
"
Standardisation of setpoint
/ target values")
[-01] = Status word
Status word, source from
P509.
[-02] = Actual value 1 (P543)
[-03] = Actual value 2 (…)
[-04] = Actual value 3 (…)
Actual values
[-05] = res.status OutBit P481
The displayed value depicts
all Bus OUT Bit sources linked
with an "OR".
[-06] = Parameter data Out 1
[-07] = Parameter data Out 2
[-08] = Parameter data Out 3
[-09] = Parameter data Out 4
[-10] = Parameter data Out 5
Data during parameter
transfer.
[-11] = Actual value 1 master funct.
[-12] = Actual value 2 master funct.
Actual value 3 master funct.
Actual value of master
function
P502 / P503.
[-14] = Status word PLC
[-15] = Actual value 1 PLC
…
[-19] = Actual value 5 PLC
Status word + Actual values to
PLC
Pos: 60 8 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 ...) /P700- P799 /Para meter P742 – Datenbankversion @ 0\mod_1328178021821_388.docx @ 13405 @ @ 1
P742
Data base version
(Database version)
S
0 ... 9999 Displays the internal database version of the FI.
Pos: 60 9 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 .. .)/P7 00-P7 99/Par amet er P743 – Umricht ert yp @ 0\mod_1328178080214_388.docx @ 13428 @ @ 1
P743
Inverter type
(Inverter type)
0.00 ... 250.00
Displays the inverter power in kW, e.g. "1.50" ⇒ FI with 1.5 kW nominal power.