NORDAC FLEX (SK 200E ... SK 235E)Users Manual for Frequency Inverters
216 BU 0200 en-3118
Pos: 60 4 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 .. .)/P7 00-P7 99/Par amet er P739 Aktuelle Temperat ur Kühl körp er [SK 1 x0E, SK 2 xxE, SK 2 xxE-FDS] @ 2\mod_1346932207653_388.docx @ 43584 @ @ 1
P739 [-01]
...
[-03]
Heat sink temp.
(Current heat sink temperature)
-40 ... 150°C
[-01] = FI heat sink temperature
[-02] = Internal temperature of the FI
[-03] = Temp. Motor KTY, motor temperature via KTY, recording exclusively via IO extension,
setting in (P400) to function {30} "Motor temperature"
Pos: 60 5 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par amet er/ Par amet erau fli st ung (P 000 .. .)/P 700- P799 /Par amet er P740 Prozessdaten Bus In [SK 1x0E, SK 2xxE, SK 500...535E, SK 2xxE-FDS] @ 0\mod_1328175248086_388.docx @ 13313 @ @ 1
P740 [-01]
...
[-19]
PZD bus In
(Process data Bus In)
S
0000 ... FFFF (hex) This parameter provides
information about the
actual control word and
the setpoints that are
transferred via the bus
systems.
For display, a BUS
system must be selected
in P509.
Standardisation:
( section
8.9
"
Standardisation of
setpoint / target values")
[-01 ] = Control word
Control word, source from
P509.
[-02] = Setpoint 1 (P510/1, P546)
[-03] = Setpoint 2 (P510/1, …)
[-04] = Setpoint 3 (P510/1, …)
Setpoint data from main
setpoint (P510 [-01]).
[-05] = res.status InBit P480
The displayed value depicts all
Bus In Bit sources linked with
an "OR".
[-06] = Parameter data In 1
[-07] = Parameter data In 2
[-08] = Parameter data In 3
[-09] = Parameter data In 4
[-10] = Parameter data In 5
Data during parameter transfer:
Order label (AK), Parameter
number (PNU), Index (IND),
Parameter value (PWE 1/2)
[-11] = Setpoint 1 (P510/2)
[-12] = Setpoint 2 (P510/2)
[-13] = Setpoint 3 (P510/2)
Setpoint data from the master
function value (Broadcast) -
(P502/P503), if P509 = 4
[-14] = Control word PLC
[-15] = Setpoint 1 PLC
[-19] = Setpoint 5 PLC
Control word + Setpoint data
from PLC
Pos: 60 6 /Allg emein/ Allg emeing ültig e Mod ule/---------Sei tenumbr uch ko mpakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1