Series EPC-30 Current-to-Pressure (I/P)
Transducer
WARNING! Allow only personnel with appropriate training and experience
to operate or service the equipment. The use of untrained or inexperienced
personnel to operate or service the equipment can result in injury, including
death, to themselves and others, and damage to the equipment.
Introduction
This instruction sheet contains the procedure for installing the
current-to-pressure (I/P) transducer (kit P/N 772033).
If the Eclipset EPC-30 pattern control is equipped with an optional
input/output (I/O) board, the I/P transducer can be installed to provide
run-up control for the system. Refer to the Eclipse EPC-30 pattern control
manual for setting the run-up control.
Specifications
The following table lists specifications for the I/P transducer.
Item Specification Note
Air supply input pressure 8.6 − 10.3 bar (125 − 150 psi) A
Air supply output pressure 0.2 − 8.3 bar (1 − 120 psi) A
Input impedance 260 ohms (nominal)
Input signal 4 − 20 mA VDC B
NOTE A: The transducer was calibrated using a 6.6−6.9 bar (95−100 psi) air supply.
B: With a 6.6−6.9 bar (95−100 psi) air supply, the output should be 0−0.3 bar (0−5 psi) with a 4 mA signal or
6.0−6.4 bar (87−93 psi) with a 20 mA signal.