Instruction Sheet
Part 331276B
02
E 2010 Nordson Corporation
P/N 331276B
02
Series EPC-30 Current-to-Pressure (I/P)
Transducer
WARNING! Allow only personnel with appropriate training and experience
to operate or service the equipment. The use of untrained or inexperienced
personnel to operate or service the equipment can result in injury, including
death, to themselves and others, and damage to the equipment.
Introduction
This instruction sheet contains the procedure for installing the
current-to-pressure (I/P) transducer (kit P/N 772033).
If the Eclipset EPC-30 pattern control is equipped with an optional
input/output (I/O) board, the I/P transducer can be installed to provide
run-up control for the system. Refer to the Eclipse EPC-30 pattern control
manual for setting the run-up control.
Specifications
The following table lists specifications for the I/P transducer.
Item Specification Note
Air supply input pressure 8.6 10.3 bar (125 150 psi) A
Air supply output pressure 0.2 8.3 bar (1 120 psi) A
Input impedance 260 ohms (nominal)
Input signal 4 20 mA VDC B
NOTE A: The transducer was calibrated using a 6.66.9 bar (95100 psi) air supply.
B: With a 6.66.9 bar (95100 psi) air supply, the output should be 00.3 bar (05 psi) with a 4 mA signal or
6.06.4 bar (8793 psi) with a 20 mA signal.
Question and Answer IconNeed help?

Do you have a question about the Nordson EPC-30 and is the answer not in the manual?

Nordson EPC-30 Specifications

General IconGeneral
BrandNordson
ModelEPC-30
CategoryTransducer
LanguageEnglish

Summary

Introduction

Specifications

I/P Transducer Installation

Transducer Cable Wire Color Code

Details the wire color code for connecting the transducer cable to the control unit.

Troubleshooting

Pneumatic Section

Details troubleshooting steps for the pneumatic components of the transducer.

Electronic Section

Details troubleshooting steps for the electronic components of the transducer.

Basic Calibration

ZERO Adjustment

Explains how to adjust the ZERO potentiometer for transducer calibration.

SPAN Adjustment

Details the procedure for adjusting the SPAN potentiometer for calibration.

Field Troubleshooting