EasyManua.ls Logo

Nordyne O4HD-091A-12-FA - User Manual

Nordyne O4HD-091A-12-FA
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
151B0801 R5 3/28/2006
1
OIL-FIRED WARM AIR
FURNACE
O4HD-091A-12-FA AND O4HD-091A-V-F
O4HD-140A-16-FA AND O4HD-140A-V-F
(UPFLOW OR HORIZONTAL MODELS)
NORDYNE
INSTALLATION
INSTRUCTIONS
Read this manual completely before beginning
installation.
Important: These instructions must be kept with
the furnace for future reference.
TABLE OF CONTENTS
INTRODUCTION ....................................................... 3
HEAT LOSS .............................................................. 3
LOCATION OF UNIT................................................. 3
AIR CONDITIONING ................................................. 4
COMBUSTION AIR ................................................... 4
CHIMNEY VENTING ................................................. 5
OIL TANK.................................................................. 7
PIPING INSTALLATION ........................................... 7
ELECTRICAL CONNECTIONS................................. 7
CIRCULATING AIR BLOWER (ECM)....................... 8
FURNACE CONTROLS ............................................ 9
OIL BURNER ............................................................ 9
FURNACE INSTALLATION SET-UP...................... 11
MAINTENANCE AND SERVICE............................. 12
OPERATING INSTRUCTIONS................................ 12
TABLE A-1: BECKETT OIL BURNER SET-UP...... 13
TABLE A-2: DIRECT DRIVE BLOWER SET-UP.... 13
TABLE A-3: DIRECT DRIVE BLOWER
CHARACTERISTICS .............................................. 14
GENERAL DIMENSIONS – O4HD MODELS ......... 15
APPENDIX A: WIRING DIAGRAM O4HD-091A-12-FA
AND O4HD-140A-16-FA ......................................... 16
APPENDIX B: WIRING DIAGRAM O4HD-091A-V-F
AND O4HD-140A-V-F ............................................. 17
WIRING NOTES ...................................................... 18
R7184 DETAILED SEQUENCE OF OPERATION .. 19
TABLE C-1: EFT DETAILED SEQUENCE OF
OPERATION ........................................................... 20
TABLE C-1: EFT DETAILED SEQUENCE OF
OPERATION ........................................................... 21
TABLE C-2: CAD CELL RESISTANCE................. 23
TABLE C-3: R7184 TROUBLESHOOTING ........... 24
TABLE C-4: SYSTEM AND GENERAL
TROUBLESHOOTING ............................................ 26
AIR FILTER LOCATION ......................................... 29
PARTS..................................................................... 30

Questions and Answers

  • S
    Sara CookAug 9, 2025
    Why Nordyne Furnace burner motor does not start?
    • M
      Melissa BrooksAug 9, 2025
      If the burner motor in your Nordyne Furnace doesn't start when there's a call for heat, several issues could be the cause. Ensure that the limit switches are closed and the contacts are clean. Check for line voltage power at the oil primary control; there should be 120 Vac between the black and white lead wires on the oil primary control. If the cad cell is defective, exposed to external light, or the connections are shorted, shield the cad cell from external light. As another solution, jumper the thermostat (T -T) terminals on R7184, but be sure to first remove one thermostat lead wire.
  • T
    Tamara CarterAug 25, 2025
    What to do if Nordyne O4HD-091A-12-FA burner starts then locks out?
    • K
      Kristen GillAug 25, 2025
      If your Nordyne Furnace burner starts and then locks out, with the indicator light flashing, there are several potential causes. First, the cad cell or controller could be defective, exposed to external light, or have shorted connections; try shielding the cad cell from external light. You can also try resetting the oil primary control by pushing in and releasing the red reset button. Listen for a spark after the burner turns on (after a 2-second delay). As another solution, jumper the thermostat (T-T) terminals on the R7184, but be sure to first remove one thermostat lead wire.

Nordyne O4HD-091A-12-FA Specifications

General IconGeneral
BrandNordyne
ModelO4HD-091A-12-FA
CategoryFurnace
BTU Output72, 000
Efficiency80%
Voltage115V
Phase1
Blower MotorPSC
Blower Speeds4
Ignition TypeDirect Spark
Gas TypeNatural Gas
Vent Size4 inches
TypeGas
BTU Input90000
Filter Size16x25 inches

Related product manuals