43
Outdoor Temperature Reset
Chapter5.–Setting
10. Press the ‘Dial Button’. The default design
warm weather temperature (70°F) will ash on
the display. Turn the ‘Dial Button’ to adjust to
the desired temperature.
11. Press the ‘Dial Button’ to conrm the setting.
9. With ‘4:Od’ displayed, press the ‘Dial Button’.
‘A:HI’ will begin ashing.
12. Turn the ‘Dial Button’ to ‘b:noH’.
13. Press the ‘Dial Button’.
‘b:noH’ will being to ash on the display.
14. Press the ‘Dial Button’.
The default setting of ON will begin to
ash on the display. Turn the ‘Dial Button’
to OFF if desired.
NOTE:
• b.noH: Toggles a xed tolerance (+5°F) for the warm weather temperature setting of ‘A:HI’.
‘ON’: Combi Boiler will stop operation when the outdoor temperature reaches ‘A:HI’ setting +5°F.
‘OFF’: Combi Boiler will operate at the lowest heating set temperature when the outdoor temperature
reaches ‘A:HI’ setting +5°F.