43
Outdoor Temperature Reset
Chapter5.–Setting
10. Press the ‘Dial Button’. The default design
warm weather temperature (70°F) will ash on
the display. Turn the ‘Dial Button’ to adjust to
the desired temperature.
11. Press the ‘Dial Button’ to conrm the setting.
9. With ‘4:Od’ displayed, press the ‘Dial Button’.
‘A:HI’ will begin ashing.
12. Turn the ‘Dial Button’ to ‘b:noH’.
13. Press the ‘Dial Button’.
‘b:noH’ will being to ash on the display.
14. Press the ‘Dial Button’.
The default setting of ON will begin to
ash on the display. Turn the ‘Dial Button’
to OFF if desired.
NOTE:
• b.noH: Toggles a xed tolerance (+5°F) for the warm weather temperature setting of ‘A:HI’.
‘ON’: Combi Boiler will stop operation when the outdoor temperature reaches ‘A:HI’ setting +5°F.
‘OFF’: Combi Boiler will operate at the lowest heating set temperature when the outdoor temperature
reaches ‘A:HI’ setting +5°F.