Avoid installation above gas ranges or stoves.
Avoid installation between the kitchen fan and stove. If oily
fumes or a large amount of steam are present in the installation
location, take measures to prevent the fumes and steam from
entering in the equipment.
Install in a location where the exhaust gas ow will not be
a󰀨ected by fans or range hoods.
Take care that noise and exhaust gas will not a󰀨ect neighbors.
Avoid installation on common walls as the unit will make some
operational noises while it is running.
Before installing, make sure that the exhaust ue termination will
have the proper clearances according to the National Fuel Gas
Code (ANSI Z223.1-latest edition) or the Natural Gas and Propane
Installation Code (CSA B149.1).
If the unit is installed in a location with very high humidity,
condensate may form inside the unit and/or cause incomplete
combustion, damage to the electrical components, or electric
leakage.
State of California: The water heater must be braced, anchored or strapped to avoid moving during an
earthquake. Contact local utilities for code requirements in your area or call: 1-866-766-7489 and
request instructions.
Be sure to do
Prohibited
Prohibited
CAUTION
The Commonwealth of Massachusetts: The water heater can be used for hot water only and not in a
combination of domestic and space heating.
For Venting Manufacturers Requirements, see websites listed below:
Noritz N-Vent www.noritz.com
The water heater is designed for indoor installation only. Never install it
outdoors or in a bathroom, it may be damaged or a re may be caused.
Consult with the customer concerning the location of installation.
Do not install the water heater near staircases or emergency exits.
Install the water heater in an area that allows for the proper clearances
to
combustible and noncombustible construction. Consult the rating plate
on the appliance for proper clearances.
Do not install the water heater in a place where it may be threatened by
falling objects, such as under shelves.
The water heater must be installed in a place where supply and exhaust
pipes can be installed as directed.
Do not install the water heater where the exhaust will blow on outer walls or
material not resistant to heat. Also consider the surrounding trees and animals.
The heat and moisture from the water heater may cause discoloration of
walls and resinous materials, or corrosion of aluminum materials.
Do not locate the vent termination directed towards a window or any other
structure which has glass or wired glass facing the termination.
Prohibited