Type | Tankless |
---|---|
Fuel Type | Natural Gas |
Flow Rate | 0.5 - 5.0 GPM |
GPM at 35°F Rise | 5.0 GPM |
Energy Factor | 0.82 |
Energy Factor Range | 0.81 - 0.83 |
Voltage | 120V |
Gas Type | Natural Gas |
Maximum BTU Input | 120, 000 BTU/hr |
Minimum BTU Input | 15, 000 BTU/h |
Venting | Outdoor |
Tips for safe operation and maintenance, including protective gear and tool usage.
Diagram identifying key components like heat exchanger, igniter, circuit board for NR50-OD, NR66-OD, N-0531S-OD.
Diagram identifying key components like heat exchanger, igniter, circuit board for NR66-SV, N-0531S.
Diagram identifying key components like heat exchanger, igniter, circuit board for NR71-OD, N-0631S-OD.
Diagram identifying key components like heat exchanger, igniter, circuit board for NR71-SV, N-0631S.
Diagram identifying key components like heat exchanger, igniter, circuit board for NR98-OD, N-0751M-OD.
Visualizes water heating logic: normal operation, errors, and component checks for NR50, NR66, NR71 series.
Detailed electrical wiring diagram for NR50-OD, showing component connections to the circuit board.
Wiring diagrams for NR66 and NR71 series, illustrating component connections to the circuit board.
Lists error codes, descriptions, diagnostics, and reset steps when a remote controller is connected.
Lists error codes, descriptions, and troubleshooting for NR71/N-0631S series without a remote controller.
Details error codes, descriptions, diagnostics, and reset procedures for NCC199, NRC111 series with remote controller.
Provides normal voltage and resistance values for circuit board components for NR50-OD, NR66, NR71 series.
Provides normal values for circuit board components for NC380-SV-ASME / N-1321M-ASME, including thermistor and burner sensor characteristics.
Explains error codes, causes, checkpoints, and reset procedures for NR50-OD, NR66, NR71 series.
Lists error codes, descriptions, diagnostics, and troubleshooting for NR98, NR111, NC380 series with optional remote controller.
Explains error codes, causes, checkpoints, and reset procedures for NR111 and NC380 series, covering fan, sensor, and pressure issues.
Guide for transferring data when replacing a circuit board in NCC199, NRC111 series, ensuring unit functionality.
Detailed steps for replacing the circuit board, including data transfer and initial settings for NR98/NR111 series.
Steps for transferring data when replacing a circuit board in NC380-SV-ASME / N-1321M-ASME models.
Instructions for setting up a new circuit board, including remote controller connection and DIP settings.
Guidelines for sizing gas lines based on btuh demand and supply pressures to ensure adequate gas delivery.
Procedure for adjusting manifold gas pressure for NR50, NR66, and NR71 series, including using set buttons and checking values.
Steps for adjusting manifold gas pressure for NR98, NC199, N-0751M series, using set buttons and referring to cover-on/off values.
Procedure for adjusting manifold gas pressure for NCC199, NRC111, NR111, NC250, N-0931M series, referencing cover-on/off values.
Steps for adjusting manifold gas pressure for NC380-SV-ASME / N-1321M-ASME, using set buttons and referencing cover-on/off values.
Items to check during inspection: combustibles, sounds, appearance, leaks, and vent conditions.
Guidelines for cleaning the unit's exterior and remote controller using appropriate methods.
Procedure for draining water using remote controller for maintenance/freeze prevention on specific models (NCC/NRC/841/842).
Step-by-step guide for manually draining water for maintenance or freeze prevention, including valve and fixture operations.
Instructions on filling the neutralizer unit with water before initial startup to prevent dangerous exhaust gas release.