Do you have a question about the Noritz NR98 Series and is the answer not in the manual?
Type | Tankless |
---|---|
Fuel Type | Natural Gas or Propane |
Maximum Flow Rate | 9.8 GPM |
Installation Type | Indoor or Outdoor |
Minimum Activation Flow Rate | 0.5 GPM |
Temperature Range | 100°F to 140°F |
Maximum BTU Input | 199, 900 BTU/hr |
Venting | 2" or 3" PVC/CPVC |
Electrical Requirements | 120V, 60Hz |
Warranty | 12-year heat exchanger, 5-year parts |
Disconnect electrical power, turn off gas and water, and remove four screws.
Remove two screws holding the GFCI plate, noting the ground wire.
Locate and remove the clamp on the gas connection to the manifold plate.
Remove three screws and pull out the fan motor with the blade attached.
Clean fan with compressed air, or water/degreaser after removing the blade.
Replace the fan motor and blade, either as a unit or separately.
Tighten fan blade nut if removed and reassemble unit following reverse steps.