Customizable Settings
Stopping Recirculation
Operation
Muting the Remote Controller
The Remote Controller will
emit a sound when any button
is pressed. This sound can be
muted if it is desired.
2. Press and hold the
button until a sound is heard
(approximately 2 seconds).
1. Press and hold the
button for 5 seconds.
4. Change the setting using the
/ buttons.
(Setting completed.)
3. Press the button several
times until the item number
“4” is displayed.
Operation
Operation
Set the button to ON when
continuing to use the unit as
is. Otherwise, let the unit sit
for approximately 30 seconds.
(Default setting = on)
on: Recirculation on
oF: Recirculation off
Flow Meter Alarm
The flow meter alarm is being
used to indicate when a tub is full.
1. The button is ON.
2. Set the temperature using
the / buttons.
Operation
Check the current setting
temperature.
The flow meter setting will be
blinking.
The maximum hot water
temperature will blink.
The flow meter alarm cannot
be muted.
The high temperature warning
tone when setting the unit to
125°F/55°C (131°F) or higher
will not emit a sound when
muted.
4. Turn on hot water.
5. Turn off the hot water when
the alarm sounds to prevent
overfilling.
The alarm will not sound if it
is set for 990 gal (990 L).
The level can only be adjusted
while the flow meter setting is
blinking.
After 10 seconds, the Remote
Controller will again display
the temperature.
When the tub fills with the
preset volume of water, an
alarm will sound alerting you
to shut off the water.
3.
Press the button, and
adjust with the / buttons.
(Default setting = 990 gal (990 L))
[For gallon]
10 - 60 gal (In 5 gal intervals),
60 - 100 gal (In 10 gal intervals),
990 gal
[For liter]
40 - 240 L (In 20 L intervals),
240 - 380 L (In 40 L intervals),
990 L
[Muted]
No sound after 5 seconds
[Sound]
The sounds after 5 seconds
1. The button is OFF.
(Default setting = Sound)
NOTE
The hot water filling
temperature is
same as the setting
temperature.
Although the
temperature can be
set to 125°F/50°C
or higher, do not set
the temperature to
125°F/50°C or higher
as it can cause severe
burns instantly or
death from scalding.
(e.g. 120°F)