This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2)
l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le onctionnement.
INTERNAL BATTERY INFORMATION
This Normatec Go control unit is equipped with a rechargeable lithium ion battery. The internal battery is designed to allow
use of the Normatec Go System anywhere—even when power outlets aren’t available. The Normatec Go control unit may
need to be charged before first use. A fully charged battery will provide power for up to 2 hours of cumulative run-time. It
takes approximately 4 hours to fully charge the battery when the control unit is plugged in and not in use. The rechargeable
lithium ion battery is intended to be changed only by authorized service personnel with the use of a special service tool.
This device contains a lithium-ion battery. Batteries are only replaceable by a skilled worker with a special tool.
Contact Hyperice for service or repair. When the battery is at end of life, the device shall be properly disposed
of. The battery must be complied with safely at an appropriate e-waste disposal or recycling facility.
PRODUCT SPECIFICATIONS
Normatec Go Model: ALJ7
Normatec Go Calf Wrap Dimensions (fully open): 25” (width), 1” (depth), 12” (height); [63.5 cm (width), 2.5 cm
(depth), 30.5 cm (height)]
Normatec Go Weight: 1.2 lbs [0.5 kg]
Normatec Go electrical requirement: 5V DC 1 A
Maximum Air Pressure: 220 mm Hg
Internal Battery Rating: 3.6V, 2550mAh/3.65V, 2600mAh
Ambient Temperature (charging): + 50 °F to 95 °F [+10 °C to 35 °C]
Temperature (operating): +41° F to 104° F [+5° C to +40° C]
Temperature (storage): -13° F to +158° F [-25° C to +70° C]
Relative Humidity (operating): 15% to 93%, non-condensing
Relative Humidity (storage): -25˚ C without relative humidity control; +70˚ C at relative humidity up to 93%,
non-condensing
Atmospheric pressure (storage and transportation): 190hPa to 1060hPa
Atmospheric pressure (operating): 700hPa to 1060hPa
ELECTROMAGNETIC COMPATIBILITY
The information contained in this section (such as separation distances) is in general specifically written with regard
to the Normatec Go. The numbers provided will not guarantee faultless operation but should provide reasonable
assurance of such. This information may not be applicable to other medical electrical equipment; older equipment
may be particularly susceptible to interference.
GENERAL NOTES
Medical electrical equipment requires special precautions regarding electromagnetic compatibility (EMC) and needs
to be installed and put into service according to the EMC information provided in this document and the remainder of
the instructions for use of this control unit.
WARNING!
Portable RF communications equipment (including peripherals such as antenna cables and external
antennas) should be used no closer than 30 cm (12 inches) to any part of the Normatec Go, including cables
specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
The Normatec Go should not be used adjacent to or stacked with other equipment. If adjacent or stacked
use is necessary, the NormatecGo should be observed to verify normal operation. If operation is not
normal, the Normatec Go or the other equipment should be moved.
Use of accessories, transducers and cables other than those specified or provided by the manufacturer
of this equipment could result in increased electromagnetic emissions or decreased electromagnetic
immunity of this equipment and result in improper operation.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NormaTec Go and is the answer not in the manual?

NormaTec Go Specifications

General IconGeneral
Charging Time2 hours
ConnectivityBluetooth
CompatibilityiOS and Android
Battery Life3 hours
ControlMobile app
Wireless Range30 feet (9 meters)