Loading...
Water is leaking
from the unit.
The body of the
ice maker is
electrified.
Scales occur
frequently inside
the machine.
Noise during
operation
The downcomer
doesn't leak.
Harvesting ice is
difficult
The ice maker
stops suddenly
while making ice.
Cubes are too big.
A few water drops fall to the
floor when you open the door
to take out ice from ice
storage bin.
Water supply connection
leaking.
Nut of the water drain hole
leaking.
Drainpipe connection
leaking.
The grounding line isn't in
the socket.
The lines are creepage.
The hardness of the water is
too high.
The sprinkler is blocked.
partially
The sprinkler pressure of
spray isn't enough.
The feet are not leveled and
locked
Certain sounds are normal.
The water line blocks
The water supply tap is turn
off.
The ambient temperature and
water temperature is too low
The electricity is off.
The room temperature is out
of the stated range.
The fuse is brown.
The voltage of the power
supply is low.
The ventilation louvers are
covered.
The ambient temperature and
water temperature is too low.
Normal condensation on the door or some
water together with ice. Take care when you
take out ice.
Tighten fitting. See "Connecting the Water
Line".
Tighten the nut.
Tighten fitting. See "Connecting the Drain".
Use the socket meeting the required
electrical standard.
Adjust, reconnect/replace lines
Use a water-softening device installed in
front of the water inlet valve.
Clean it; see "Interior Cleaning".
Check.the water quality The water line
may be blocked
Level and lock the feet. See "Leveling the
Ice Maker".
See "Normal Sounds".
Clean it, see user and care manual "ice
making system cleaning"
Turn on the water supply tap.
Adjust the temperature.
Reconnect the power supply line.
Cut off the electricity; let the ice maker stop
working till the temperature returns within
the stated range.
Replace fuse.
Add manostat.
Remove the obstruction.
Adjust the temperature.
28