LP & HIGH ALTITUDE LP GAS CONVERSION KIT FOR INSTALLATIONS IN CANADA
BEFORE THE CONVERSION
IMPORTANT: Please read all instructions before
converting the furnace. Pay attention to all safety warnings
and any other special notes highlighted in the manual. Safety
markings are used frequently throughout this manual to
designate a degree or level of seriousness and should not
be ignored. WARNING indicates a potentially hazardous
situation that if not avoided, could result in personal injury
or death.
This conversion kit is only to be used to convert natural
gas furnaces to LP/Propane gas in the United States. For
installations in Canada, the Canadian conversion kit must
be used.
Table 1 is a detailed listing of the components in the LP gas
conversion kit. Please check the contents of the conversion
kit with that of the parts listing, and familiarize yourself with
each component.
Use caution when servicing or removing components from
the appliance. Personal injury can occur from sharp metal
edges present in all sheet metal constructed equipment.
IMPORTANT: When converting a low NOx furnace from
natural gas to LP/Propane gas, it is necessary to remove
the NOx Baffles from the furnace.
For *G7 / *GC2 & GUH* / GDD* Series Furnaces & Appliances Using Honeywell Gas Valves
INSTALLATION INSTRUCTIONS
WARNING AVERTISSEMENT
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury or property damage.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
• If you cannot reach your gas supplier, call
the fire department.
RISQUE D’INCENDIE OU D’EXPLOSION
Le non-respect des avertissements de sécurité
pourrait entraîner des blessures graves ou des
dommages matériels.
L’installation et l’entretien doivent être effectués
par un installateur qualifié, un organisme de service
ou le fournisseur de gaz.
Ne pas entreposer ni utiliser de l’essence ni
d’autres vapeurs ou liquides inflammables dans le
voisinage de cet appareil, ni de tout autre appareil.
QUE FAIRE S’IL Y A UNE ODEUR DE GAZ
Ne tenter d’allumer aucun appareil.
Ne toucher à aucun interrupteur électrique;
n’utiliser aucun téléphone dans le bâtiment.
Évacuer l’immeuble immédiatement.
Appeler immédiatement le fournisseur de gaz en
employant le téléphone d’un voisin. Respecter les
instructions du fournisseur de gaz.
Si personne ne répond, appeler le service des
incendies.
DO NOT DESTROY. PLEASE READ CAREFULLY &
KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
NE PAS DÉTRUIRE. VEUILLEZ LIRE ATTENTIVEMENT ET
CONSERVER EN UN LIEU SÛR POUR RÉFÉRENCE ULTÉRIEURE.
Table 1. LP Gas Conversion Kit
DESCRIPTION QTY
Honeywell Conversion Kit 396221
(to convert VR8205S2890 or VR8215S1289)
1
Honeywell Conversion Kit 396021
(to convert VR8205Q2381)
1
Honeywell Conversion Kit 50033841
(to convert VR9205Q1127)
1
#55 Drill Size Burner Orifice Kit
(contains (7) 661055)
1
#56 Drill Size Burner Orifice Kit
(contains (7) 661056)
1
#57 Drill Size Burner Orifice Kit
(contains (7) 661057)
1
#59 Drill Size Burner Orifice Kit
(contains (3) 661059)
1
#60 Drill Size Burner Orifice Kit
(contains (3) 661060)
1
Conversion Warning Label 1
Conversion Information Label 1
Installation Instructions 1

Questions and Answers

  • C
    chanmartinNov 5, 2025
    What to do if my Nortek G7 fails to operate?
    • S
      smithwilliamNov 5, 2025
      If your Nortek Furnace fails to operate, start by ensuring the thermostat is operating properly. Also, check if the blower compartment door(s) are securely in place and that the furnace disconnect is closed. Verify that the circuit breaker hasn't tripped or the control board fuse hasn't burned open, and that the gas supply is turned on. Inspect for any open manual reset switches and ensure the filter isn't dirty or plugged. Clean a coated flame sensor with steel wool, check for blockage in the condensate drain switch, make sure the secondary heat exchanger is free of debris and clogs, and ensure the evaporator coil is clean. Finally, check if all the LEDs on the furnace and motor control boards are constantly ON, and check the Blower Limit Switch and Flame Rollout Switch, resetting them if...

Nortek G7 Series Specifications

General IconGeneral
Heating Capacity40, 000 to 120, 000 BTU/h
Fuel TypeNatural Gas
Blower MotorECM
Heat ExchangerStainless steel
StagesTwo-stage
Warranty10-year limited