24
1. There should be no obstruction near air inlet and air outlet.
2. Select a location where the condensation water can be drained easily and
won't drip on people, animals, other's property, etc.
3. Select a location which is convenient to connect the outdoor unit and near the
power socket.
4. Select a location which is out of reach for children.
5. The support structure should have sufficient load-carrying capacity to support
the weight of the unit. The unit should be securely mounted to avoid vibration.
7. Don't install the indoor unit right above an electric appliance.
Tools for installation
Selection of installation location
1 Level 2 Screw driver 3 Impact drill
4 Drill bit 5 Pipe expander 6 Torque wrench
7 Open-end wrench 8 Pipe cutter 9 Leakage detector
10 Vacuum pump 11 Pressure meter 12 Multi-meter
13 Hexagon wrench 14 Measuring tape
Note:
Ɣ3OHDVHFRQWDFWWKHORFDODJHQWIRULQVWDOODWLRQ
Basic requirement
Indoor unit
Installing the unit in the following places may cause malfunction.
1. Places with strong heat sources, , or
volatile objects spread in the air.
2. Places with high-frequency devices (such as welding machine, medical
equipment).
3. Coastal regions.
4.
The place with oil other fumes in the air.
5. Places with high sulfur gas concentration in the air.
6. Other places with special circumstances.
7. Do not use the unit in a laundry, bath, shower, or indoor swimming pool.
2.5m(8 ft)
It's best to keep unit as far as possible from fluorescent lamps.