4-10 Introduction to RSC-S International
297-8331-815 Standard 10.01 August 1999
Preparing to datafill RSC-S UK/Europe
PCL—New Software Delivery Vehicle
After BCS36, Northern Telecom delivers Product Computing-Module Loads
(PCL) instead of BCS releases or Universal Software Loads (USL).
A PCL has features selected from the development stream software product
intended for an application in a market. The PCL contains the abilities
divided before, in different related NTX packages. An 8-digit order code
replaces the NTX package codes.
The order codes and Functional group names required for the RSC-S appear
in the following table. A list of the old NTX packages that the Functional
group includes, appears in the following table. These capabilities associate
with the RSC-S.
RSC-S order codes
Ordering code Functionality
Functional
group name
Old NTX package codes
BAS00012 BAS Remotes
Generic
NTX145AA—Remote Switching
Center
NTX149AB—RSC ESA-Lines and
Trunks
NTX150AA—RSC-Intra RSC
Calling
NTXP92AA—RSC-S Basic
NTXQ12AA—RSC Enhanced
ESA (Lines)
BAS00026 BAS00036 BAS Int’l Remote
Generic
NTXK77AA—PCM-30 RSCO-S
Support
NI000007 NI0 ISDN Base NTX750AD—ISDN Basic Access
Collecting end-user data
When the RSC-S includes ISDN, collect the profiles of the subscriber sets to
enter the profiles.