Nouvag HighSurg 30 - User Manual

Nouvag HighSurg 30
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Motor System for Surgery
© NOUVAG AG • 31666 • V20221117 • All rights reserved.
HighSurg 30
Instructions for use
EN

Other manuals for Nouvag HighSurg 30

Questions and Answers

  • L
    Leah AndersonAug 15, 2025
    What to do if the Nouvag HighSurg 30 device is not operational?
    • M
      Michael SmithAug 15, 2025
      If your Nouvag Medical Equipment device isn't working, there are several things to check: * Ensure the control unit is switched on by setting the power switch to “I”. * Verify the power connection to the mains power supply. * Check the mains voltage to ensure it's correct. * Replace the fuse if it's faulty. * In case of a processor error, switch the main switch to “I”, wait 10 seconds, and then switch it back to “O”.
  • M
    Mitchell EdwardsAug 18, 2025
    What to do if the Nouvag HighSurg 30 motor does not run?
    • B
      bburnsAug 18, 2025
      If the motor of your Nouvag Medical Equipment isn't running, consider the following: * Make sure the motor is switched on using the treadplate. * Try switching to the other motor using the VARIO pedal. * Ensure the motor cable is securely connected to the control unit. * Check that the handpiece or contra angle is correctly assembled by firmly pressing it onto the electronic motor until it clicks and is secure.
  • H
    hodgerandyAug 21, 2025
    What to do if the Nouvag HighSurg 30 pedal is not operational?
    • C
      clinedonnaAug 21, 2025
      If the pedal of your Nouvag Medical Equipment is not working, check that the pedal is correctly connected to the control unit. Also, review the operating instructions to ensure correct operation.
  • V
    vwagnerAug 25, 2025
    Why is there no irrigation fluid for the instrument in my Nouvag Medical Equipment?
    • A
      Anthony MurphyAug 26, 2025
      If there is no irrigation fluid for the instrument in your Nouvag Medical Equipment, consider the following possible causes: * Ensure the peristaltic pump is switched on. * Check that the tubing set is correctly inserted, noting the direction. * Replace the tubing set if it's clogged or shows visible crusting. * Open the ventilation filter at the drip chamber if the bottle with sodium chloride solution is not ventilated. * Replace the tubing set if it is dripping. * Open the roller clamp completely if it's closed. * Use the tube set recommended by Nouvag, ensuring it is the correct type.
  • C
    Christopher MccoyAug 28, 2025
    What to do if the display of my Nouvag HighSurg 30 Medical Equipment is illuminated red?
    • A
      acarrAug 28, 2025
      If the display of your Nouvag Medical Equipment is illuminated red, it could be due to the motor not being connected. Ensure the motor is properly connected. Alternatively, the motor or cable may be defective; in this case, check the motor and cable for any issues.
  • K
    Kelly RichardsAug 31, 2025
    What to do if my Nouvag HighSurg 30 device is not functional?
    • W
      William LeonardAug 31, 2025
      If your Nouvag Medical Equipment device isn't working, first ensure the control unit is switched on by setting the power switch « I/O » to « I ». Also, verify the power connection to the mains power supply and check that the mains voltage is correct. A faulty fuse could also be the issue, so consider replacing it. Finally, a processor error might be the cause; try setting the power switch « I/O » to « O », wait 10 seconds, and then switch it back to « I ».
  • A
    Angela Terry DVMSep 3, 2025
    What to do if the motor doesn’t work in my Nouvag Medical Equipment?
    • M
      Melanie HernandezSep 3, 2025
      If the motor of your Nouvag Medical Equipment isn’t working, make sure it's switched on using the step plate. If that doesn't work, the incorrect motor might be active; try switching to the other motor using the VARIO pedal. Also, check that the motor cable is securely connected to the control unit. Finally, ensure the handpiece or contra angle is correctly assembled by firmly pressing it onto the electronic motor until it clicks and is secure.
  • L
    Lori JonesSep 7, 2025
    What to do if my Nouvag Medical Equipment device is not operational?
    • J
      Jacqueline MarshallSep 7, 2025
      If your Nouvag Medical Equipment device isn't working, first ensure the power switch “I/O” is set to “I”. Then, verify the power connection to the mains supply. Check that the mains voltage is correct. Finally, inspect and replace the fuse if necessary.
  • J
    Julie HurstSep 12, 2025
    What to do if the motor does not run on my Nouvag Medical Equipment?
    • M
      Maria GomezSep 12, 2025
      If the motor on your Nouvag Medical Equipment isn't running, make sure you've switched it on using the treadplate. Try switching to the other motor using the Vario pedal. Check that the motor cable is securely connected to the control unit. Also, ensure the handpiece or contra angle is correctly assembled by pressing it firmly onto the electronic motor until it clicks and is secure.

Nouvag HighSurg 30 Specifications

General IconGeneral
ModelHighSurg 30
ManufacturerNouvag
TypeSurgical Unit
ModesCoagulation
Voltage100-240 V