MT 3060 User Guide 19
Up / Down (Vertical Acceleration)
Up and down accelerometer events can be triggered when the threshold is exceeded as determined by
the accelerometer in milli-Gs (for example, 0.75) for a defined period of time in seconds (for example, 30
seconds). The command may also be configured to clear the event if it persists beyond a maximum
duration.
Example:
The following AT command example sets the vertical acceleration threshold 1 to 1.2Gs. If this threshold
is exceeded for 1 second, an input event is triggered. This event clears in 30 seconds when the
acceleration is below this threshold. The event also clears if the threshold is exceeded for a duration of
10 seconds.
AT$DVBVAL=1,1200,1,30,10