S h o r t
1 2
C o n t i n u e ?
N o y e s
At the moment, push key (No) to exit calibration function. Push key (Yes)
to repeat the measurement.
Note:If the tester is restarted after it shuts off, the tester will recoverthe
standard calibration factor of Class UTP5 cable as setupbefore shipment.
Start up or shut down AF hunting function
(1). Press PUSH key,the hunting indicator light (SCAN) flashes,which indicates that
audio frequency transmission of main tester is normal, inert wire to be hunted into
LAN cable hunting port with RJ45” pattern. If RJ11/USB/BNC and other cable can
be directly inserted corresponding port, su ch as, RJ11/USB /BN C; the n hunt wi re
required with receiving end (the usage of receiver is shown in the following).
After the hunting is completed,press PUSH key again,PUSH key springs out,hunting
indicator light (SCAN) turns off and then cable order test function and length test
function can be used.
-11-
(2).The user can turn volume switch to control the volume.
(3).The floodlight function facilitates the user's operation in dark environment.
(4).Earphone function, the earphone can be worn in noisy environment for
operation so as to avoid external interference.
(5).The cable order test function and length test function can not be used in hunting.
Usage of the receiver
Dismount the battery cover, install battery of 9V, take the receiver with thumb
pressing “PUSH” key, then approach the cable with probe and find target wire
required in numerous cables. When the probe is near target wire, the “beep, beep
and beep” sound may occur and the signal indicator light “POWER” will turn on.
Compare volume of “beep, beep and beep” and luminance of signal indicator light,
the wire of which the sound is the loudest and the signal indicator light is the
brightest is target wire required.
At the moment, push key (No) to exit calibration function. Push key
(Yes) to repeat the measurement.