Introduction
Units are rectangular in section and consist of three basic
designs.
Full size access panels are fitted to the top of the units and
are fully detachable for inspection and connection purposes.
The models are coded as follows:
EST-X (External/Internal Duct Mounted) in line unit.
EST-R (Roof Mounted, end inlet) side discharge unit.
EST-B (Roof Mounted bottom inlet) side discharge unit.
EST-X units are rectangular in section and have circular rigid
spigots at each end.
EST-R units are rectangular in section and are supplied with
a circular end spigot and two opposed side discharge grilles.
EST-B units are rectangular in section and have a rectangular
bottom spigot and two opposed side discharge grilles.
Handling
Always handle the units carefully to avoid damage and
distortion. If mechanical aids are used to lift the unit, spreaders
should be employed and positioned so as to prevent the slings,
webbing etc. making contact with the casing.
Installation
Installers - please note that Installation must be carried
out by competent personnel in accordance with the
appropriate authority and conforming to all statutory and
governing regulations e.g. I.E.E, CIBSE, COHSE.
EST-X/R/B units are suitable for internal or external use.
All units can be installed at any angle up to 60
o
however, on a
sloping roof the unit must be blowing upwards toward the
roof ridge to ensure correct backdraught shutter operation.
Units should always be positioned with sufficient space to
allow removal of the access cover and subsequent removal
of fan and motor assemblies etc.
Whether internally or externally mounted, the method of fixing
to the roof is the responsibility of the installer.
All units have a bottom skirt to allow for fixing directly onto
a suitably sized curb or builders upstand. Nuaire can supply a
matching prefabricated curb for these units. Details of curbs
and dimensions for a suitable external concrete upstand are
shown on page 2.
Ductwork connections must be airtight to prevent any loss of
performance.
Table 1. EST-X Dimensions (mm)
Weight
Code ABCD dia. (kg)
EST1-X 705 505 355 125 22
EST2-X 875 720 400 200 35
EST3-X 970 720 485 200 50
EST4-X 1165 980 575 250 72
EST5-X 1165 980 575 400 75
EST6-X 1165 980 575 400 86
EST9-X 1495 1125 710 500 162
Weight
Unit ABCD dia. EF(kg)
EST1-R 705 505 355 125 - - 22
EST1-B 705 505 355 - 76 152 22
EST2-R 875 720 400 200 --35
EST2-B 875 720 400 - 127 229 35
EST3-R 970 720 485 200 --45
EST3-B 970 720 485 - 127 229 45
EST4-R 1165 980 575 250 --72
EST4-B 1165 980 575 - 152 305 72
EST5-R 1165 980 575 400 --75
EST5-B 1165 980 575 - 229 457 75
EST6-R 1165 980 575 400 --86
EST6-B 1165 980 575 - 229 457 86
EST9-R 1495 1125 710 500 --162
EST9-B 1495 1125 710 - 304 762 162
External
Commissioning box
D
C
A
B
Removable
top panel
Control module
located internally
EST-X
EST-R & EST-B
A
B
Removable
top panel
Commissioning box
Opposed
outlet
grille
Circular inlet spigot
on end of unit
Code: EST*-R
D
E
F
Control module
located internally
C
Rectangular bottom
inlet spigot EST*- B only
16. 06. 15. Leaflet Number 671142
Figure 1. EST-X unit.
Figure 2. EST-R/B units.
ECOSMART TWINFANS
(EST-X/R/B) 1 phase, Direct Drive,
Run & Standby
For External, Roof Mounted and Internal use
Installation and Maintenance
The EMC Directive
2014/30/EU
The Low Voltage
directive
2014/35/EU
Table 2. EST-R / B Dimensions (mm)
In High humidity applications above 90%
trickle ventilation is recommended.
Question and Answer IconNeed help?

Do you have a question about the NuAire ECOSMART TWINFAN Series and is the answer not in the manual?

NuAire ECOSMART TWINFAN Series Specifications

General IconGeneral
BrandNuAire
ModelECOSMART TWINFAN Series
CategoryFan
LanguageEnglish

Summary

Introduction to ECOSMART Twinfans

Unit Designs and Safe Handling

Describes the three basic unit designs and provides handling instructions to prevent damage.

Installation Requirements and Compliance

Guidance for competent personnel, regulatory compliance, and mounting.

Prefabricated Curb and Roof Mounting

Prefabricated Curb Codes and Dimensions

Lists typical prefabricated curb codes and their dimensions for installation.

Roof Opening and Curb Dimensions

Details dimensions for roof curbs and opening sizes for various unit models.

Electrical Systems and Wiring

Electrical Details and Testing Procedures

Covers electrical specifications, testing after installation, and wiring connections.

I/O Connections and Data Cabling

Details control, damper, relay, and data connections, including data cable installation.

BMS Integration and Airflow Control

BMS Input Signal Interpretation

Details system response to O-IOV dc BMS signals based on ventilation mode.

Setting Fan Airflow Rates

Instructions for setting maximum and minimum airflow using adjustment pots.

Unit Status Indicators and Controls

Understanding LED Status Lights

Explains the meaning of various LED indicators for power, status, and communication.

Using the Test Button for Operation

Instructions on how to use the test button to check fan operation and sequence.

Maintenance and Component Replacement

Scheduled Maintenance and Cleaning

Recommended schedule for first and subsequent maintenance, plus cleaning procedures.

Fan Motor Assembly Replacement

Instructions for replacing fan/motor assemblies and ordering spare parts.

Warranty, Support, and Safety

Product Warranty and After Sales Support

Details of the 5-year warranty and contact information for technical assistance.

Comprehensive Safety Information

General Safety and Documentation

General statements, documentation overview, and handling precautions.

Installation, Operation, and Commissioning

Covers installation requirements, operational limits, and commissioning procedures.

Maintenance and Fault Management

Specific maintenance requirements, tools, isolation, and fault handling protocols.

Related product manuals