OM0123 Page 1 of 68
Rev 15
Water-Jacketed,
US Autoflow Automatic CO
2
Incubator
Models
NU-4750, NU-4850, NU-4950
NU-4750D, NU-4850D, NU-4950D
NU-4750E, NU-4850E, NU-4950E
Operation & Maintenance Manual
July, 2013
Revision 15
Series 10 4750
Series 5 4750D
Series 10 4750E
Series 11 4850
Series 7 4850D
Series 11 4850E
Series 11 4950
Series 7 4950D
Series 11 4950E
For 115 Vac, 60 Hz Only
Manufactured By:
NuAire, Inc.
2100 Fernbrook Lane
Plymouth, MN 55447
Toll-Free: 1-800-328-3352
In Minnesota: (763)-553-1270
Fax: (763)-553-0459
Question and Answer IconNeed help?

Do you have a question about the NuAire NU-4750 and is the answer not in the manual?

NuAire NU-4750 Specifications

General IconGeneral
BrandNuAire
ModelNU-4750
CategoryAccessories
LanguageEnglish

Summary

General Description

Extra Large (20 gallon) Water-Jacket

Details the water-jacket construction, insulation, and its role in temperature uniformity.

NuAire Incubator Control Electronics

Describes the microcomputer-based control system (NICE) and its components.

CO2 Display and Control

Relative Humidity Display and Control (NU-4850, NU-4950)

O2 Display and Control (NU-4950)

Safety Instructions

Performance Parameters

Chamber Water-Jacket Capacity and Uniformity

Details the 20-gallon water-jacket and its ±0.2°C temperature uniformity.

Temperature Control System

Explains the dual-sensor temperature control system and algorithm.

CO2 Percentage Control

Describes the use of an infrared gas analyzer for CO2 monitoring and control.

Models, Features & Specifications

NU-4750 Standard Features

Lists standard features for the NU-4750 model, including construction and control systems.

Test Performance & Procedures

Electrical Tests

Describes electrical leakage, dielectric voltage, and grounding continuity tests.

Functional Tests

Lists functional tests performed after the burn-in period, including control systems.

Warranty

Shipments

Damaged Shipments

Outlines procedures for inspecting shipments and filing claims for damage.

Installation

Location

Advises on selecting an appropriate location considering performance and lab procedures.

Electrical

Filling & Draining the Water-Jacket

CO2/N2* Tube Connection

CO2/N2 Pressure Regulators

US Autoflow Operation

Humidity

Explains the humidification process for NU-4750 and NU-4850/4950 series.

System Introduction

Simplified Operator Controls

Describes the control panel layout and operator interaction with keypads.

Automatic Notification of Abnormal Situations

Explains how the system notifies users of faults and alarm conditions.

Diagnostic and Calibration Assists

Front Control Panel

Alarm Status LED

US Autoflow Rear Panel

Run Mode Operator Interactions

Setup Mode Operator Interactions

Chamber Temperature, CO2%, Humidity Percent, O2% Setpoint

Details how to set temperature, CO2, humidity, and O2 setpoints.

Automatic Adjustment of Post Inject Delay Times

Diagnostic Interactions

Diagnostic Mode Tests

Explains how to access and navigate diagnostic mode menus.

Test Output Parameters

Option Configuration Parameters

Closed Door CO2 Zero/Span Calibration

Allows zero/span calibration without opening the incubator door.

Humidity Control Alarm Enable (4850 & 4950 only)

Enables or disables the humidity control fault alarm.

Auto Zero Enable

CO2 Inject Delay Time

N-Gas Inject Delay Time (NU-4950)

RH Inject Delay Time (NU-4850 & 4950)

Temperature Time Out

CO2 Time Out

O2 Time Out (NU-4950 Only)

RH Time Out (NU-4850 & 4950)

Temperature Sensor Differential

Temperature Maximum Above Setpoint

CO2 Maximum Above Setpoint

O2 Maximum Under Setpoint (NU-4950)

RH Maximum Above Setpoint (NU-4850 & 4950)

Reset, Master

Calibration

Chamber Temperature Calibration

Step-by-step guide for calibrating the chamber temperature sensor.

Door Temperature Calibration

Door heater duty cycle automatic control

Details the automatic adjustment of the door heater duty cycle.

CO₂ Calibration

CO₂ Control Calibration

Details the procedure for CO2 control calibration.

CO2 System Auto Zero Calibration Function

Explains the automatic CO2 zero calibration routine.

CO2 Sensor Calibration (Zero/Span)

CO2 Injection Calibration

Relative Humidity Calibration (NU-4850, NU-4950)

Relative humidity calibration

Step-by-step guide for calibrating the RH sensor using a water pan.

Oxygen Sensor Calibration (NU-4950)

Maintaining Your US Autoflow

Filter Maintenance

Instructions for replacing various filters used in the system.

Shutting down the Incubator

Chemical Decontamination of the Incubator Chamber

Error Indicators & Troubleshooting

Temperature System Errors

Details errors related to temperature control and their corrections.

CO2 System Errors

Lists CO2 system errors and their corresponding troubleshooting steps.

RH Percent Errors

O2 Percent Errors

Memory Chip Faults

Power Supply Errors

Remote Alarm Contacts

Electrical/Environmental Requirements