Do you have a question about the Nuova Simonelli APPIA life 1 Group and is the answer not in the manual?
Type | Espresso Machine |
---|---|
Groups | 1 |
Pump | Rotary |
Material | Stainless Steel |
Steam Wand | Yes |
Hot Water Dispenser | Yes |
Water Supply | Plumbed |
Ensure the installation area is compatible with the machine's size and weight.
Connect the machine to the water supply, observing specifications. Filter maintenance is buyer's responsibility.
Before connecting, verify machine data plate matches mains voltage.
Adjust hot water temperature by turning the screw clockwise (increase) or counterclockwise (decrease).
Machine automatically loads water for 90 seconds. Technician must replace water thrice after installation.
Adjust boiler pressure and pump pressure via screws for desired coffee characteristics.
Press the ON/OFF key (6) to turn the machine on or off. Disconnect for maintenance.
Steps to prepare coffee: insert filter, fill with coffee, press, clean portafilter, purge group, insert portafilter, press button.
Use steam nozzle carefully. Purge condensation. Pull/push lever to control steam. Nozzles are articulated.
Immerse steam nozzle in milk, turn on steam, adjust nozzle position, clean nozzle after use.
Use hot water nozzle carefully. Purge hydraulic circuit. Place container, press button (P1) to dispense.
Access programming by holding the continuous delivery key (P4) for 5 seconds.
Programme water amount for delivery keys (P2, P3, P5, P6) by filling filter and pressing keys.
Enter programming, press hot water key (P1), set desired amount, press again.
Set pre-set values for 4 group doses and water (steam) by pressing and holding key (P4).
Program EasyCream steam wand by pressing steam selection key.
Access machine operating parameters by holding key (P4). Options include pump activation, keypad brightness.
Clean work area by removing grid and tray. Clean external plates with damp cloth.
Clean coffee-holders weekly. Unscrew, slide out, check and clean holes if obstructed.
Perform automatic cleaning cycle with powder cleanser daily. Repeat operations.
Soak filter and filter-holder in cleanser solution for at least half an hour. Rinse thoroughly.
Regularly regenerate ionic resins to maintain softener efficiency and prevent scale.
Schematic of the electrical system for the 1-group machine.
Schematic of the electrical system for the V 1-group machine.
Diagram of the hydraulic system for the 1-group machine.
Diagram illustrating the boiler components for the 1-group machine.