Do you have a question about the Nussbaum ATT BM 35 Touch and is the answer not in the manual?
Brand | Nussbaum |
---|---|
Model | ATT BM 35 Touch |
Category | Wheel Balancers |
Language | English |
General safety precautions before, during, and after servicing the machine.
Steps to loosen, remove, replace, and tension the drive belt.
Location of the main switch and its use as an emergency off switch.
Steps to remove and replace the main switch on the machine.
Explanation of electrical connections and contacts for the main switch.
Steps for disconnecting cables, removing the motor, and installing a new one.
Steps to disconnect, loosen, remove, clean, grease, and install piezo sensors.
Procedure for removing and replacing the opto encoder board.
How to remove and replace the motor controller board.
Describes the functions, display, and physical location of the basic board.
Steps for unplugging, removing, and replacing the basic board.
Explains Flash ROM concept and updating Touch PC software first.
Steps to prepare the basic board, including shutting down and switching a jumper.
Download source and steps to update the Touch PC software using a USB stick.
Reiteration of the caution to update Touch PC software first.
Explains the zero run function for compensating unbalance of adaptor or clamping means.
Details the calibration procedure using the calibration weight and adapter.
Steps for calibration with manual wheel clamping.
Steps for calibration with QuickSpan clamping.
Allows checking various actual values for machine failure analysis.
Procedure for calibrating the distance, diameter, and width gauges.
Important note that no cone should be used for QuickSpan calibration/zero run.
Warns that running without oil can cause system malfunction.
Emphasizes performing calibration and a zero run after repair.
Warning to disconnect air supply to prevent unexpected unclamping and damage.
Performing a zero run after installing the adapter.
Performing a zero run after retrofitting the mid centring device.
Addresses E7 index error, E10 direction error, and E11 motor drive problems.
Addresses the issue of the display not illuminating upon machine startup.
Problems causing fluctuating results and their potential causes and solutions.
Issues preventing the achievement of 0-0 balance after corrections.
Verifying opto encoder mounting and main shaft free running.
Ensuring piezo sensors are fitted correctly to avoid false readings or damage.
Issues with incorrect distance and diameter readings from the inside arm.
Machine not reacting to button presses on monitor models.
Machine failing to start in automatic mode after closing the wheel guard.
The Quick Span clamping mechanism not functioning correctly.