Page 32 of 54
TOUCH PC BALANCERS
When the area with the software version is touched twice coming from the fist screen a service
screen will be displayed.
In this screen there is an overview over all the functions
A Actual distance of inner gauge arm
The reference is the edge of the cabinet and when the gauge arm is in home position it
should be 50 mm +- 10
B Actual diameter of inner gauge arm
The reference is the edge of the cabinet and when the gauge arm is in home position it
should be 260 mm +- 10
C Actual width
The reference is the edge of the cabinet and when the gauge arm is in home position it
should be 556 mm +- 10
D Temperature
The temperature is measured in a range of 200 to 700 (corresponds to -20°C to +70°C)
Temp < -20° C, Outside measuring range - Temp > 70° C, Outside measuring range
Cal. = Temperature at which the machine was calibrated
Act. = Actual temperature in 1/10 °C