1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1.
Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in
the warranty.
2.
Before servicing or cleaning unit, switch power off at service panel and lock the service disconnect-ing means to prevent power from being switched on
accidentally. When the service disconnect-ing means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service
panel.
3.
It is recommended to wear safety glasses and gloves during installation.
4.
Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable
codes and standards, including fire-
rated construction codes and standards.
5.
Sufficient air is needed for proper combus-tion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards suc
h as those published by the National Fire
Protection
Association
(NFPA),
and the American Society for Heating, Refrigeration and Air Condi-tioning Engineers (ASHRAE), and the local code
authorities.
6.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
7.
Ducted fans must always be vented to the out-doors.
8.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit
Interrupter) - protected branch circuit.
9.
Never place a switch where it can be reached from a tub or shower.
10. This unit must be grounded.
11.
Monitor your fan for unusual sounds, smells and smoke. If any appear, turn off the fan immediately and replace it.
FAN/LIGHT/SPEAKER VENTILATOR
SPK80L & SPK80NL
READ AND SAVE
THESE INSTRUCTIONS
Question and Answer IconNeed help?

Do you have a question about the NuTone SPK80L and is the answer not in the manual?

Summary

General Safety Instructions

Mandatory Safety Precautions

Critical safety guidelines covering installation, servicing, grounding, and operational monitoring to prevent hazards.

Important Cautions

Usage and Installation Restrictions

Cautions regarding ventilation use, installation location, and maintenance to ensure proper operation and safety.

Typical Installations

Mounting to Joists and Trusses

Illustrates common methods for mounting the housing to joists (2x6, 'I' joist) and trusses, detailing duct discharge orientation.

Truss, I-Joist, and Suspended Ceiling Mounting

Details on installing housing to 2x4 trusses, 'I' joists with 90° discharge, and suspended ceilings using wire mounts.

Install the Housing

Cooking Area Exclusion Zone

Specifies areas where the fan housing should not be installed, particularly above cooking equipment.

New Construction Installation

Mounting Housing to Joists

Step-by-step guide for mounting the housing to ceiling joists, including positioning for different ceiling thicknesses.

Existing Construction Installation

Ceiling Opening and Mounting

Instructions for cutting ceiling openings and mounting the housing to joists or framing, with options for difficult access.

Install the Ductwork

Duct Connector and Airflow

Procedure for attaching the duct connector with damper and ensuring proper airflow, including taping connections.

Connect the Wiring

Wiring Diagram and Connections

Detailed wiring diagram for connecting the unit to the power supply, including dual control and receptacle connections.

Attach the Grille

Grille Installation Steps

Instructions for attaching the grille using springs and connecting the grille connector to the receptacle.

Use and Care

Bluetooth, Lighting, Motor, and Cleaning

Covers Bluetooth pairing, non-serviceable lighting, permanently lubricated motor, and cleaning procedures for the unit.

Overview

This document describes the installation, use, and maintenance of the Broan-NuTone SPK80L & SPK80NL Fan/Light/Speaker Ventilator.

Function Description

The SPK80L and SPK80NL are multi-functional ceiling-mounted units designed for general ventilation. They combine a fan for air exhaust, a light for illumination, and a Bluetooth® speaker for audio playback. These units are intended for use in ceilings with up to a 12/12 pitch and are not suitable for wall mounting or for exhausting hazardous or explosive materials and vapors. They are specifically designed for ceiling installation and ductwork must point upwards.

Important Technical Specifications

  • Model Numbers: SPK80L & SPK80NL
  • Installation Type: Ceiling-mounted only, suitable for ceilings up to a 12/12 pitch.
  • Ductwork: Requires 4-inch round ducting vented to the outdoors. Ductwork must point up.
  • Framing Requirements:
    • For direct mounting to 2x6 (or larger) joists, discharge parallel to joists.
    • For mounting to 2x4 trusses or "I" joists, additional 2x6 (minimum) framing is required for mounting tabs. Discharge can be parallel or 90° to joists depending on the installation type.
    • For mounting to additional framing, discharge 90° to joists.
    • Suspended ceilings require a 3-point mount with wires.
  • Electrical:
    • 120 VAC line input.
    • Must be grounded.
    • If installed over a tub or shower, it must be connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.
    • Installation work and electrical wiring must comply with all applicable codes and standards, including fire-rated construction codes.
  • Safety Features:
    • Counter-balanced damper flap to prevent backdraft and allow insulation contact.
    • Warning against installing above or inside a cooking area.
    • Requires sufficient air for proper combustion and exhausting of gases from fuel-burning equipment to prevent backdrafting, following NFPA and ASHRAE guidelines.
    • Includes a prominent warning device (tag) for service panel lockout during maintenance.
    • Emphasizes wearing safety glasses and gloves during installation.
    • Prohibits placing a switch where it can be reached from a tub or shower.

Usage Features

  • Ventilation: Provides exhaust ventilation for general use.
  • Lighting: Includes a lighting element.
  • Bluetooth® Speaker: Features an integrated Bluetooth® speaker. To connect, turn on the light, access Bluetooth® settings on a smart device, and select "Fan Speaker" from the available devices.
  • Controls: Designed for use with a dual control switch (purchased separately) for light and fan functions.
  • Installation Flexibility: Offers various mounting options for different ceiling joist/truss types (2x6, 2x4 truss, "I" joist, additional framing, suspended ceilings) and discharge directions (parallel or 90° to joists).
  • Ceiling Material Compatibility: Includes positioning features for various ceiling material thicknesses (1/2", 5/8", 1", 1-1/4").

Maintenance Features

  • Cleaning:
    • Preventative Maintenance: Regular cleaning of the grille and interior unit is recommended for quiet, efficient operation, long life, and appearance.
    • Lens and Grille: Unplug the light from the white receptacle. Plastic parts can be cleaned with mild, soapy water (e.g., dishwashing liquid) and dried with a soft cloth. Abrasive cloths, steel wool pads, or scouring powders should not be used.
    • Fan Assembly: Unplug the fan assembly from the black receptacle. To remove the motor plate, locate the single tab on the motor plate (next to the receptacles), push up near the tab while pushing out on the side of the housing, or insert a straight-blade screwdriver into the slot in the housing (next to the tab) and twist. Gently vacuum the fan, motor, and interior of the housing with a dusting brush attachment. Metal and electrical parts should never be immersed in water.
  • Motor Lubrication: The motor is permanently lubricated and does not require oiling or disassembly.
  • Lighting Element Replacement: The lighting element is not serviceable. The light/speaker module should not be removed or disassembled.
  • Safety During Maintenance: Always disconnect electrical power supply and lock out the service panel before cleaning or servicing the unit.
  • Troubleshooting: Monitor the fan for unusual sounds, smells, or smoke. If any appear, turn off the fan immediately and replace it.